Key result
LGE CMR microvascular injury correlates with intracoronary Doppler early systolic retrograde flow in 53% of patients.
Why the study?
CMR has been used to detect and quantify microvascular obstruction after acute MI, but had never been compared with coronary blood flow velocity patterns.
Does the assessment of microvascular obstruction by LGE CMR correlate with intracoronary Doppler flow measurements in patients with acute anterior MI treated with primary PCI?
Observational (n=27)
Does the assessment of microvascular obstruction by LGE CMR correlate with intracoronary Doppler flow measurements in patients with acute anterior MI treated with primary PCI?
Noninvasive assessment of microvascular injury by LGE CMR correlates well with invasive intracoronary Doppler flow measurements in patients with acute anterior MI.
Answers are grounded in this paper and cite their sources.
LGE CMR may noninvasively gauge microvascular obstruction severity in anterior MI; leaves open whether it can supplant invasive Doppler in practice.
Objectives: We studied the relation between presence and severity of microvascular obstruction (MO), measured by cardiovascular magnetic resonance (CMR) and intracoronary Doppler flow measurements, for assessment of myocardial reperfusion in patients with acute anterior myocardial infarction (MI) treated by primary percutaneous coronary intervention (PCI). Background: Cardiovascular magnetic resonance has been used to detect and quantify MO in patients after acute MI but has never been compared with coronary blood flow velocity patterns. Methods: Twenty-seven patients with first anterior ST-segment elevation MI successfully treated with primary PCI were included. Coronary blood flow velocity was measured during recatheterization 4 to 8 days after primary PCI. These measurements were related to MO determined by late gadolinium-enhanced (LGE) CMR performed the day before recatheterization. Results: Early systolic retrograde flow was observed in 0 of 8 patients without MO on LGE CMR and in 10 (53%) of 19 patients with MO (p = 0.01). The extent of MO correlated with the diastolic-systolic velocity ratio (r = 0.44; p = 0.02), diastolic deceleration time (r = -0.61; p = 0.001), diastolic deceleration rate (r = 0.75; p < 0.0001), and coronary flow velocity reserve of the infarct-related artery (r = -0.44; p = 0.02). Furthermore, multivariate regression analyses, including extent of MO, infarct size, and transmural necrosis on LGE CMR, revealed that extent of MO was the only independent factor related to early systolic retrograde flow and diastolic deceleration rate. Conclusions: Assessment of microvascular injury by LGE CMR corresponds well to evaluation by intracoronary Doppler flow measurements. By means of CMR, quantification of myocardial function, infarct size, and microvascular injury can accurately be performed with a single noninvasive technique in patients with acute MI.
No takes yet. Share an insight, caveat, or question.
Hirsch et al. (2008) conducted an observational in Acute anterior ST-segment elevation myocardial infarction (n=27). Cardiovascular magnetic resonance (CMR) vs. Intracoronary Doppler flow measurements was evaluated on Early systolic retrograde flow (p=0.01). Assessment of microvascular injury by LGE CMR correlated with intracoronary Doppler flow measurements, including early systolic retrograde flow.
Synapse has enriched 10 related papers. Consider them for comparative context: