March 25, 2025Journal of Arrhythmia1 citationsOpen Access

Does organized atrial tachycardia after a pulmonary vein isolation‐only procedure portend better outcome of repeat ablation compared to recurrent atrial fibrillation?

View Full Paper
TRT RieszGBGábor BencsikLSLászló Sághy

Key Result

Repeat ablation for recurrent organized atrial tachycardia after index PVI did not yield better arrhythmia-free survival compared to recurrent atrial fibrillation (49% vs 52%, p=0.72).

Study Design

Type

Cohort (n=185)

Structured PICO

Does repeat ablation for recurrent organized atrial tachycardia improve arrhythmia-free survival compared to recurrent atrial fibrillation in patients with prior PVI-only ablation?

P
Population
185 patients (88 female, 64 ± 9 years) undergoing repeat ablation after index pulmonary vein isolation (PVI) for recurrent organized atrial tachycardia (24%) or atrial fibrillation (76%)
I
Intervention
Repeat ablation for recurrent organized atrial tachycardia (OAT)
C
Comparator
Repeat ablation for recurrent atrial fibrillation (AF)
O
Outcome
Recurrence rate and arrhythmia-free survival time

After a PVI-only index procedure, recurrent organized atrial tachycardia is not associated with a better outcome of repeat ablation compared to recurrent atrial fibrillation.

Main Result

Absolute Event Rate: 49% vs 52%

p-value: p=0.72

Abstract

Abstract Background Better outcome has been suggested for repeat procedures after atrial fibrillation (AF) ablation, when recurrence presented as organized atrial tachycardia (OAT) compared to recurrent AF. However, this contradicts the finding of more advanced atrial remodeling in patients with OAT recurrence and may be related to iatrogenesis by substrate modification during the index procedure. Therefore, we examined the prognostic significance of the type of recurrent arrhythmia after pulmonary vein isolation (PVI) without additional substrate modification. Methods We included 185 patients (88 female, 64 ± 9 years) undergoing repeat ablation after index PVI for recurrent OAT (24%) or AF (76%). The recurrence rate, arrhythmia‐free survival time, and the type of further recurrences were recorded. Results There was no difference in the rate and mean time of arrhythmia‐free survival between patients with OAT versus AF recurrence after the first (49% vs. 52%, p = .72 and 51.08 ± 6.66 vs. 53.37 ± 4.75 months, p = .54, respectively) and last (60% vs. 58%, p = .80 and 63.2 ± 7.04 vs. 61.2 ± 5.32 months, p = .23, respectively) redo procedure. AF occurred in the majority of subsequently recurring patients in both groups. No significant difference was found in the outcome of redo procedures between patients with typical flutter and atypical OAT, but a higher rate of successful rhythm control was observed in those with paroxysmal, as compared to persistent AF recurrence. Conclusion After a PVI‐only index procedure, recurrent OAT is not associated with a better outcome of redo procedures compared to recurrent AF. After repeat ablations, both groups experience AF as the dominant further recurrence.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Riesz et al. (2025) conducted a cohort in Recurrent organized atrial tachycardia or atrial fibrillation after pulmonary vein isolation (n=185). Repeat ablation for recurrent organized atrial tachycardia (OAT) vs. Repeat ablation for recurrent atrial fibrillation (AF) was evaluated on Arrhythmia-free survival rate after the first redo procedure (p=0.72). Repeat ablation for recurrent organized atrial tachycardia after index PVI did not yield better arrhythmia-free survival compared to recurrent atrial fibrillation (49% vs 52%, p=0.72).