Key result
Remote tele-6MWT strongly correlates with standard 6MWT but achieves only ~49% completion.
Why the study?
Remote exercise tests for patients with PH could improve telemedicine strategies, but their validity and feasibility required assessment.
Are remote exercise tests valid and feasible compared to the standard 6MWT in patients with pulmonary hypertension?
Observational
Are remote exercise tests valid and feasible compared to the standard 6MWT in patients with pulmonary hypertension?
Effect estimate: Correlation: T6MWT 0.93, ST 0.78, STS 0.71, TUG -0.76
p-value: p=<0.001
Remote exercise testing is feasible and valid in patients with pulmonary hypertension, particularly the tele-6MWT, though limited patient completion rates and high discontinuation may impact its clinical utility.
Remote exercise tests for patients with pulmonary hypertension (PH) would improve the telemedicine strategies in this disease. The PHRET study assessed the validity and feasibility of four remote exercise tests performed by PH patients at home. Participants undergoing diagnostic assessment for PH were included. At baseline, patients completed a 6MWT followed by a range of study tests including a Timed Up and Go (TUG) test, a Sit‐to‐Stand (STS), a Step Test (ST), and a tele‐6MWT (T6MWT) performed outside using a GPS‐enabled smartphone. Patients performed these tests at home following discharge and at first follow‐up. Analysis focused on comparing the results of study tests to the standard 6MWT. The discontinuation rate was 15%. Ninety‐seven percent of patients were able to complete a TUG, 92% a STS, 73% a ST, and 49% a T6MWT. At baseline, correlation between the standard 6MWT and study tests, respectively, was T6MWT 0.93, ST 0.78, STS 0.71, and TUG −0.76 ( p < 0.001). Direction of change in the study test agreed with the standard 6MWT in 68% of the follow‐up ST, 68% of the STS, 71% of the TUG, and 79% of the T6MWT. Patients were able to complete the tests at home, there were no adverse incidents and ≥92% of patients were happy to continue performing home tests. Remote exercise testing is feasible. The T6MWT was a valid remote measure of exercise capacity, but could only be performed by a limited number of patients. The high discontinuation rate may impact the utility of remote tests.
No takes yet. Share an insight, caveat, or question.
Stubbs et al. (2023) conducted an observational in Pulmonary hypertension. Remote exercise tests (TUG, STS, ST, T6MWT) vs. Standard 6-minute walk test (6MWT) was evaluated on Correlation between standard 6MWT and remote study tests at baseline (Correlation: T6MWT 0.93, ST 0.78, STS 0.71, TUG -0.76, p=<0.001). Remote exercise testing using the tele-6MWT strongly correlated with the standard 6MWT (r=0.93, p<0.001), but feasibility was limited as only 49% of patients could complete it.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: