Key result
A universal ELISA procedure using human monoclonal antibodies successfully and specifically detected D-antigen of both conventional and Sabin inactivated poliovirus vaccines.
Why the study?
Slight immunological differences between wild and attenuated strains challenge IPV potency testing, as some ELISA reagents for conventional IPV may not suit Sabin IPV.
A new universal ELISA using human monoclonal antibodies can accurately quantify D-antigen in both conventional and Sabin inactivated poliovirus vaccines, though separate reference standards are required for each.
Answers are grounded in this paper and cite their sources.
May aid standardized D-antigen quantification for IPV production; leaves open validation and adoption of type-specific standards.
To address the biosafety and biosecurity concerns related to the manufacture of inactivated polio vaccine (IPV), several manufacturers started producing it from attenuated Sabin strains. Slight immunological differences between wild and attenuated strains create a challenge for testing IPV potency, which is defined as the content of protective D-antigen determined in an ELISA test. Some ELISA reagents selected for testing conventional IPV made from wild strains (cIPV) may not be suitable for testing Sabin IPV (sIPV). This paper describes an ELISA procedure using human monoclonal antibodies selected to capture equally well both wild and attenuated strains of poliovirus. A unique monoclonal antibody neutralizing all three serotypes of poliovirus was used as the detection antibody. The method was shown to detect only D-antigen of both conventional and Sabin IPV and to be strictly serotype-specific. The method is highly sensitive and robust and produces linear results in a wide range of concentrations. We have also found that reference standards used for measuring potency of cIPV and sIPV must be made from respective vaccines. This makes it impossible to cross-calibrate potency reagents made from heterologous vaccine and requires the establishment of a new unit to measure potency of sIPV that is different from conventional D-antigen unit.
No takes yet. Share an insight, caveat, or question.
Kouiavskaia et al. (2019) studied Poliovirus vaccine potency testing. Universal ELISA procedure was evaluated on Detection of D-antigen of conventional and Sabin IPV. A universal ELISA procedure using human monoclonal antibodies successfully and specifically detected D-antigen of both conventional and Sabin inactivated poliovirus vaccines.
Synapse has enriched 10 related papers. Consider them for comparative context: