Why the study?
The immediate influence of TAVR on central cardiac measures assessed by pulse wave analysis, including subendocardial perfusion and contractility, had not been investigated.
Does TAVR improve subendocardial perfusion and contractility assessed by pulse wave analysis in patients with severe aortic stenosis?
Does TAVR improve subendocardial perfusion and contractility assessed by pulse wave analysis in patients with severe aortic stenosis?
TAVR significantly improves subendocardial perfusion and contractility as measured non-invasively by pulse wave analysis in patients with severe aortic stenosis.
BACKGROUND: Pulse wave analysis (PWA) is a useful tool for non-invasive assessment of central cardiac measures as subendocardial perfusion (Subendocardial Viability Ratio, SEVR) or contractility (dP/dtmax). The immediate influence of transcatheter aortic valve replacement (TAVR) on these indices has not been investigated yet. METHODS: We prospectively enrolled 40 patients presenting with severe aortic stenosis receiving TAVR. Central pressure curves were derived from radial and carotid sites using PWA up to 2 days before and 7 days after TAVR. Parameters were compared between peripheral measurement sites. Changes in SEVR, dP/dtmax and in indices of vascular stiffness were assessed. Additionally, association of these variables with clinical outcome was evaluated during a 12-month follow-up. RESULTS: Central waveform parameters were comparable between measurement sites. SEVR, but not dP/dtmax, augmentation Index (AIx) or augmentation pressure height (AGPH) correlated significantly with disease severity reflected by peak transvalvular velocity and mean transvalvular pressure gradient over the aortic valve (Vmax, ΔPm) [r = -0.372,p = 0.029 for Vmax and r = -0.371,p = 0.021 for ΔPm]. Vmax decreased from 4.5m/s (IQR:4.1-5.0) to 2.2m/s (IQR:1.9-2.7), (p<0.001). This resulted in a significant increase in SEVR [135.3%(IQR:115.5-150.8) vs. 140.3%(IQR:123.0-172.5),p = 0.039] and dP/dtmax [666mmHg(IQR:489-891) vs. 927mmHg(IQR:693-1092),p<0.001], and a reduction in AIx [154.8%(IQR:138.3-171.0) vs. 133.5%(IQR:128.3-151.8),p<0.001] and AGPH [34.1%(IQR:26.8-39.0) vs. 25.0%(IQR 21.8-33.7),p = 0.002], confirming the beneficial effects of replacing the stenotic valve. No association of these parameters could be revealed with outcome. CONCLUSIONS: PWA is suitable for assessing coronary microcirculation and contractility mirrored by SEVR and maxdP/dt in the setting of aortic stenosis. PWA parameters attributed to vascular properties should be interpreted with caution.
No takes yet. Share an insight, caveat, or question.
Müller et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: