Why the study?
The study aimed to compare the frequency and timing of cardiac arrhythmia detection and evaluate the clinical and economic impact of remote telemetry versus in-person follow-up in elderly and senile patients after dual-chamber pacemaker implantation.
Does remote telemetry improve the timing of cardiac arrhythmia detection and cost-effectiveness in elderly patients following dual-chamber pacemaker implantation compared to in-person follow-up?
Does remote telemetry improve the timing of cardiac arrhythmia detection and cost-effectiveness in elderly patients following dual-chamber pacemaker implantation compared to in-person follow-up?
Remote telemetry after dual-chamber pacemaker implantation enables earlier detection of arrhythmias and is more cost-effective than standard in-person follow-up in elderly patients.
May support remote monitoring for earlier detection after pacemaker implantation; leaves open need for RCTs before practice change.
Aim . To compare the frequency and timing of cardiac arrhythmia detection and conduct a clinical and economic analysis of remote telemetry (RT) in elderly and senile patients following dual-chamber pacemaker (PM) implantation compared to in-person clinical follow-up over a 12-month period. Methods . A prospective study was conducted involving 92 patients (50% female), with a mean age of 71,5 years. The intervention group (n=39) was monitored remotely using the Medtronic CareLink Network, USA, with patients transmitting data monthly for one year. The control group (n=53) underwent in-person clinical follow-ups at one month and one year post-implantation. The groups were comparable in age, sex, clinical diagnoses, and complications (p>0,05). A cost-effectiveness analysis (CEA) was performed, and the cost-effectiveness ratio (CER) was calculated. Results . No statistically significant differences were observed between the experimental and control groups in the frequency of cardiac arrhythmias. However, significant differences were found in the timing of arrhythmia detection (p<0,001), with earlier detection in the experimental group. According to the results of the clinical and economic costeffectiveness analysis, the CER value for the remote monitoring method (33226,30 [33226,30; 33226,30]) is statistically significantly lower than the similar coefficient for in-person diagnostics (373542,00 [3735,42; 373542,00]). Conclusion . The use of RT in elderly and senile patients following dual-chamber PM implantation did not show a statistical difference in arrhythmia detection rates. However, cardiac arrhythmias were diagnosed earlier in the experi mental group. The cost-effectiveness analysis demonstrated that RT requires lower financial costs to achieve a unit of effectiveness compared to in-person monitoring.
No takes yet. Share an insight, caveat, or question.
Peshkov et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: