Under sensorless control, the position estimation error in interior permanent magnet (PM) synchronous machines will lead to parameter identification errors and a rank-deficiency issue. This paper proposes a parameter identification model that is independent of position error by combining the dq-axis voltage equations. Then, a novel dual signal alternate injection method is proposed to address the rank-deficiency issue, i.e., during one injection period, a zero, positive, and negative d-axis current injection together with a rotor position offset injection, to simultaneously identify the multi-parameters, including stator resistance, dq-axis inductances, and PM flux linkage. The proposed method is verified by experiments at different dq-axis current conditions.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: