Why the study?
Determining underlying mechanisms of AF and VF, such as multiple-wavelets versus rotational drivers, may help tailor treatment strategies, but whether global fibrillation organisation can be determined from ECGs was unknown.
Does an ECG classification framework using band-power feature analysis accurately predict fibrillation organization levels in rat VF and human AF?
Does an ECG classification framework using band-power feature analysis accurately predict fibrillation organization levels in rat VF and human AF?
Answers are grounded in this paper and cite their sources.
A novel machine learning framework using band-power features from surface ECGs can non-invasively distinguish between different global organization levels of atrial and ventricular fibrillation.
Background: Atrial fibrillation (AF) and ventricular fibrillation (VF) are complex heart rhythm disorders and may be sustained by distinct electrophysiological mechanisms. Disorganised self-perpetuating multiple-wavelets and organised rotational drivers (RDs) localising to specific areas are both possible mechanisms by which fibrillation is sustained. Determining the underlying mechanisms of fibrillation may be helpful in tailoring treatment strategies. We investigated whether global fibrillation organisation, a surrogate for fibrillation mechanism, can be determined from electrocardiograms (ECGs) using band-power (BP) feature analysis and machine learning. Methods: In this study, we proposed a novel ECG classification framework to differentiate fibrillation organisation levels. BP features were derived from surface ECGs and fed to a linear discriminant analysis classifier to predict fibrillation organisation level. Two datasets, single-channel ECGs of rat VF ( n = 9) and 12-lead ECGs of human AF ( n = 17), were used for model evaluation in a leave-one-out (LOO) manner. Results: The proposed method correctly predicted the organisation level from rat VF ECG with the sensitivity of 75%, specificity of 80%, and accuracy of 78%, and from clinical AF ECG with the sensitivity of 80%, specificity of 92%, and accuracy of 88%. Conclusion: Our proposed method can distinguish between AF/VF of different global organisation levels non-invasively from the ECG alone. This may aid in patient selection and guiding mechanism-directed tailored treatment strategies.
No takes yet. Share an insight, caveat, or question.
Li et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: