Answers are grounded in this paper and cite their sources.
Micro thermoelectric device (μ-TED) emerges with great attention in energy generation, thermal management, and heat sensing applications. However, the large sensitive area is necessary to accommodate enough thermoelectric couples (TCs) for a high thermoelectric performance. This limits the potential in micro energy harvesting and ultra-sensitive sensing applications. Here, we adopted an optimized MEMS-based process to fabricate the ultra-sensitive micro-thermoelectric device (μ-TED). With the help of MEMS-compatible electrochemical deposition, the small size (25 μm), high aspect ratio (1:1.25), and alternating distributed P/N structures are achieved. As a result, the μ-TED realizes an ultra-high integration density of 19,900 thermoelectric couples per cm 2 . Moreover, it shows a great thermoelectric sensitivity of 212 mV/(K·cm 2 ) and a competitive power factor of 0.51 μW/(K 2 ·cm 2 ), which means the μ-TED is competent for miniaturized applications. Additionally, the μ-TED shows an ultra-low detection limit of 5 mm/s and a short response time of 100 ms, revealing great potential in fast detections of the ultra-low airflow. Furthermore, the ultra-sensitive μ-TED is utilized as a flexible breath sensor, due to its compact size. The breath signal of different motion states is successfully detected. These results confirm that the ultra-sensitive μ-TED holds outstanding potential for ultra-sensitive airflow sensing and energy harvesting devices.
No takes yet. Share an insight, caveat, or question.
Yan et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: