Answers are grounded in this paper and cite their sources.
This study provides a comparison of three methods, i.e., standard locally weighted averaging (LWA), least-norm solutions, and l1-minimization, for model-free predictive control based on Just-In-Time modeling and database maintenance for an unstable system. In contrast to conventional model predictive control, the model-free predictive control method does not use any mathematical model; rather, it uses the past input/output data stored in a database. Although conventional stabilizing feedback is used to obtain the input/output data of an unstable system, model-free predictive control is assumed to be used without it. Three methods based on standard LWA, least-norm solutions, and l1-minimization are statistically compared using a simple model. The results show that the methods of least-norm solutions and l1-minimization are superior to that of LWA. The method by l1-minimization yields tracking errors smaller than that by least-norm solutions; however, the method by l1-minimization requires a long computational time. In addition, the effectiveness of a method of database maintenance is illustrated by numerical simulations.
No takes yet. Share an insight, caveat, or question.
Saputra et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: