Why the study?
Autonomic nervous system imbalance is common worldwide, prompting the development of an integrated system to measure and affect autonomic status.
Does photobiomodulation at specific acupuncture points alter heart rate variability and autonomic nervous system status?
Does photobiomodulation at specific acupuncture points alter heart rate variability and autonomic nervous system status?
A prototype wearable system combining PPG and photobiomodulation demonstrated feasibility in measuring and acutely modulating autonomic nervous system tone via targeted acupoint stimulation.
Acute autonomic modulation via light acupuncture is feasible in one case; leaves open translation to clinical cardiovascular use.
(1) Background: The imbalance of the autonomic nervous system (ANS) is common worldwide. Many people have high tension when the sympathetic nervous system is hyperactive or low attention when the parasympathetic nervous system is hyperactive. To improve autonomic imbalance, a feasible and integrated system was proposed to measure and affect the ANS status. (2) Methods: The proposed system consists of a signal-processing module, an LED stimulation module, a photoplethysmography (PPG) sensor and an LCD display. The heart rate variability (HRV) and ANS status can be analyzed from PPG data. To confirm HRV analysis from PPG data, an electrocardiogram (ECG) device was also used to measure HRV. Additionally, photobiomodulation (PBM) was used to affect the ANS status, and two acupuncture points (Neiguan (PC6) and Shenmen (HT7)) were stimulated with different frequencies (10 Hz and 40 Hz) of PBM. (3) Results: Two subjects were tested with the developed system. HRV metrics were discussed in the time domain and frequency domain. HRV metrics have a similar change trend on PPG and ECG signals. In addition, the SDNN was increased, and the parasympathetic nervous system (PNS: HF (%)) was enhanced with a 10 Hz pulse rate stimulation at the Neiguan acupoint (PC6). Furthermore, the SDNN was increased, and the sympathetic nervous system (SNS: LF (%)) was enhanced with a 40 Hz pulse rate stimulation at the Shenmen (HT7) acupoint. (4) Conclusion: A prototype to measure and affect the ANS was proposed, and the functions were feasible. The test results show that stimulating the Neiguan (PC6) acupoint can inhibit the SNS. In contrast, stimulating the Shenmen (HT7) acupoint can activate the SNS. However, more experiments must be conducted to confirm the effect by choosing different pulse rates, dosages and acupoints.
No takes yet. Share an insight, caveat, or question.
Shan et al. (2023) studied Healthy volunteers (pilot test) (n=2). Photobiomodulation (Light acupuncture) vs. Baseline was evaluated on Change in heart rate variability (HRV) metrics (SDNN, HF%, LF%).