Key result
Radiofrequency ablation of premature ventricular contractions originating from left ventricular papillary muscles achieved a 96% acute success rate despite a low mean contact force of 3.1 grams.
Why the study?
The minimal contact force value required for ablation of arrhythmias arising from left ventricular papillary muscles is not known.
Does radiofrequency catheter ablation reduce premature ventricular complexes in patients with left ventricular papillary muscle ectopy, and what contact force is required?
Observational (n=24)
No
Does radiofrequency catheter ablation reduce premature ventricular complexes in patients with left ventricular papillary muscle ectopy, and what contact force is required?
Successful radiofrequency ablation of ventricular ectopy originating from left ventricular papillary muscles can be achieved with much lower contact force values (~3.0 g) than the 8.0-10.0 g typically recommended for other left ventricular sites.
Answers are grounded in this paper and cite their sources.
May allow reduced contact force targets for papillary muscle PVC ablation; leaves open prospective validation of durability.
Background Good catheter-tissue contact is mandatory to create effective ablation lesions. The minimal contact force value for ablation of arrhythmias originating from the left ventricle is 8.0–10.0 grams but is not known for arrhythmias arising from papillary muscles. Purpose To analyze contact force values during successful ablation procedures of arrhythmias originating from the left ventricular papillary muscles. Methods 24 consecutive patients (mean age 57.9 ± 11.9 years, 16 males) underwent ablation of premature ventricular complexes originating from left ventricular papillary muscles with the use of CARTO electro-anatomical system and intracardiac echocardiography. Results Acute complete abolition of ventricular ectopy was obtained in 23 (96%) patients. The fluoroscopy time was 3.9 ± 3.5 min and procedure duration - 114.8 ± 37.9 min. The mean contact force during successful ablations was 3.0 ± 1.1 grams and 3.18 ± 1.8 grams for antero-lateral and postero-medial papillary muscle, respectively (NS). The mean contact force during a single unsuccessful ablation was 3.0 grams. At control Holter ECG, the mean Ectopy Burden was Reduced in the Antero-Lateral Papillary Muscle Group from 18.0% ± 7.9% to 2.6% ± 2.9% ( p = 0.005415) and in the Postero-Medial Papillary Muscle Group - from 34.8% ± 13.7%–1.7% ± 1.3% ( p = 0.012694). During Median 27 (IQR: 17–34) Months of Follow-up There one Recurrence of Arrhythmia. Conclusion The values of contact force for successful ablation of ventricular ectopy originating from the left ventricular papillary muscles may be much lower than those for ablation of other foci which questions the role of contact force measurement when ablating these arrhythmias.
No takes yet. Share an insight, caveat, or question.
Baran et al. (2023) conducted an observational in Premature ventricular contractions originating from left ventricular papillary muscles (n=24). Radiofrequency catheter ablation guided by intracardiac echocardiography was evaluated on Acute procedural success (complete abolition of ventricular ectopy). Radiofrequency ablation of premature ventricular contractions originating from left ventricular papillary muscles achieved a 96% acute success rate despite a low mean contact force of 3.1 grams.