Key result
Performing transfemoral TAVI in patients deemed ineligible by manufacturer criteria resulted in similar rates of major vascular complications compared to eligible patients.
Why the study?
Up to one-third of TAVI candidates may be unsuitable for transfemoral TAVI based on manufacturers' recommendations, but the predictive value of these guidelines for major vascular access site complications requires investigation.
Does performing TF-TAVI in patients deemed ineligible by manufacturer criteria increase major vascular complications compared to eligible patients?
Cohort (n=208)
Does performing TF-TAVI in patients deemed ineligible by manufacturer criteria increase major vascular complications compared to eligible patients?
Manufacturer criteria alone may not accurately predict major vascular complications in TF-TAVI, and additional factors like sheath-to-femoral artery ratio should be incorporated into clinical decision-making.
Answers are grounded in this paper and cite their sources.
Similar rates suggest manufacturer criteria may overestimate vascular risk in TF-TAVI; leaves open prospective validation of SFAR-guided selection.
Up to one-third of patients indicated for transcatheter aortic valve implantation (TAVI) may be unsuitable for transfemoral TAVI (TF-TAVI) according to manufacturers’ recommendations and numerous professional societies. This study aimed to investigate the predictive value of manufacturers’ guidelines for major vascular access site complications using the Perclose ProGlide device. Among 208 patients undergoing TF-TAVI, 144 patients (69.2%) were deemed eligible for TF-TAVI according to the manufacturer's instructions. A minimal lumen diameter (MLD) of the femoral artery below the manufacturer's specified limits and/or the presence of circumferential calcification were the reasons for ineligibility. Calcium score (CS), sheath-to-femoral artery ratio (SFAR) and MLD were estimated from computed tomography imaging. Vascular complications (VCs) (defined according to VARC-2 criteria) were retrospectively compared. Patients in the ineligible group had higher SFAR (1.13±0.15 vs. 0.88±0.107, p<0.001) and CS (1.66±0.99 vs. 1.24±0.73; p=0.003), and significantly lower MLD (7.72±1.03 vs. 6.31±0.96 mm; p<0.001) compared to the eligible group. Major (6.3% vs. 12.3%, p=0.13) and minor VCs (10.4% vs. 15.6%, p=0.29) were similar in the eligible and ineligible groups. The ineligible group had higher rates of rupture (0.7% vs. 6.3%; p=0.03). SFAR was the only independent predictor of major VCs (OR 469.1, 95% CI 4.95-44 466.57, p=0.008). The TAVI team should not decide whether the patient is suitable for a femoral approach based solely on the manufacturer's criteria, and should incorporate additional factors that could be predictive of major VCs. Até um terço dos doentes pode não ser elegível para implantação de válvula aórtica percutânea transfemoral (TAVI-TF) devido a recomendações do fabricante e de múltiplas sociedades profissionais. Investigar o valor preditivo das recomendações do fabricante nas complicações major no local de acesso vascular utilizando o dispositivo Perclose Proglide. De 208 doentes submetidos a TAVI-TF, 144 (69,2%) foram considerados elegíveis para TAVI-TF de acordo com as instruções do fabricante. Um diâmetro mínimo do lúmen iliofemoral (DMLI) abaixo dos limites especificados pelos fabricantes e/ou a presença de calcificação concêntrica constituíram as razões de não indiciação/elegibilidade. O score de calcificação (SC), a relação bainha-artéria femoral (RBAF) e o DMLI foram avaliados através de tomografia computorizada. As complicações vasculares (CV) (definidas segundo os critérios VARC-II) foram comparadas retrospetivamente. Os doentes do grupo não elegível apresentaram valores mais elevados de RBAF (1,13±0,15 versus 0,88±0,107, p<0,001), SC (1,66±0,99 versus 1,24±0,73; p=0,003) e valores significativamente mais baixos de DMLI (7,72±1,03 versus 6,31±0,96; p<0,001) quando comparados com o grupo elegível. As CV major (6,3% versus 12,3%, p=0,13) e minor (10,4% versus 15,6%, p=0,29) foram semelhantes nos dois grupos. O grupo não elegível apresentou taxa de rotura mais elevada (0,7% versus 6,3%; p=0,03). A RBAF foi o único fator preditivo independente de CV major (OR 469,1 [IC] 95% 4,95-44 466,57, p=0,008). A equipa responsável pela TAVI não deve decidir a elegibilidade para a abordagem femoral com base apenas nos critérios do fabricante, devendo incorporar na avaliação fatores adicionais que possam ser preditivos de complicações vasculares major.
No takes yet. Share an insight, caveat, or question.
Çakal et al. (2022) conducted a cohort in Transfemoral transcatheter aortic valve implantation (TF-TAVI) (n=208). Transfemoral TAVI in patients ineligible by manufacturer criteria vs. Transfemoral TAVI in eligible patients was evaluated on Major vascular complications (p=0.13). Performing transfemoral TAVI in patients deemed ineligible by manufacturer criteria resulted in similar rates of major vascular complications compared to eligible patients.
Synapse has enriched 10 related papers. Consider them for comparative context: