Key result
The Impella CP device provided safe and effective perioperative hemodynamic support in a high-risk patient undergoing off-pump coronary artery bypass grafting, resulting in an uncomplicated recovery.
Why the study?
OPCABG may be performed in high-risk patients who are poor candidates for traditional mechanical circulatory support, but micro-axial hemodynamic support has limited reported data.
Does the Impella CP device provide safe and effective hemodynamic support in high-risk patients undergoing off-pump coronary artery bypass grafting?
Case Report (n=1)
No
Does the Impella CP device provide safe and effective hemodynamic support in high-risk patients undergoing off-pump coronary artery bypass grafting?
Answers are grounded in this paper and cite their sources.
The Impella CP device can be safely and effectively used for perioperative hemodynamic support in high-risk patients undergoing off-pump coronary artery bypass grafting.
Off-pump coronary artery bypass grafting (OPCABG) may be performed on patients with high surgical risk who are poor candidates for traditional mechanical circulatory support. Hemodynamic support with micro-axial mechanical circulatory devices has been performed with limited but promising results.We report a case of a 66-year-old male with multiple comorbidities and low cardiac output undergoing OPCABG. Impella CP device was deployed for "in-pump" support during surgical coronary revascularization resulting in intraoperative stability and uncomplicated post-operative recovery.Previous reports have described the use of the Impella Recover LP 5.0 device for use during OPCABG. We describe the successful and safe perioperative use of the Impella CP device. Despite lower flow rates, adequate support was achieved and the transfemoral cannulation and smaller outer diameter than the Impella 5.0 device may decrease the risk of complications and expedite recovery. Further research will be necessary to determine the optimal perioperative hemodynamic support strategy to offer hemodynamically unstable, high, and prohibitive risk patients.
No takes yet. Share an insight, caveat, or question.
Upadhyaya et al. (2021) conducted a case report in Severe coronary artery disease with low ejection fraction undergoing off-pump CABG (n=1). Impella CP device was evaluated on Intraoperative stability and uncomplicated post-operative recovery. The Impella CP device provided safe and effective perioperative hemodynamic support in a high-risk patient undergoing off-pump coronary artery bypass grafting, resulting in an uncomplicated recovery.
Synapse has enriched 10 related papers. Consider them for comparative context: