Key result
An implanted Amplatzer Cardiac Plug left atrial appendage occlusion device caused deformation of the left superior pulmonary vein in a patient referred for atrial fibrillation catheter ablation.
This case report highlights the anatomical considerations, specifically device deformation of the pulmonary vein, when performing catheter ablation in a patient with a pre-existing left atrial appendage occlusion device.
Alerts operators to possible LAA device-related pulmonary vein distortion during AF ablation; leaves open prevalence and procedural impact.
A 60-year-old woman with atrial fibrillation (AF) and prior implantation of an Amplatzer Cardiac Plug (ACP) left atrial appendage (LAA) occlusion device was referred for ablation. A pre-procedural transoesophageal echocardiography revealed device deformation of the anterior aspect of the left superior pulmonary vein …
No takes yet. Share an insight, caveat, or question.
Steckman et al. (2014) studied this question. An implanted Amplatzer Cardiac Plug left atrial appendage occlusion device caused deformation of the left superior pulmonary vein in a patient referred for atrial fibrillation catheter ablation.