Objective: The jugular venous pulse (JVP) is a pivotal clinical parameter that currently can only be invasively measured through jugular catheterization and subsequent central venous pressure measurement. The ultrasound B-mode clip of the internal jugular vein cross-sectional area modifications allows to build a JVP curve that significantly correlates with the central venous pressure. However, this process is time-consuming and not suitable for clinical use. The aim of the present study is to verify whether artificial intelligence (AI) allows a rapid and reliable JVP waveform assessment as compared with a human operator. Methods: High-resolution B-mode internal jugular vein clips (558 frames) of a cohort of six human subjects have been blindly analysed in post-processing by three different researchers and a neural network. Agreement was quantified using two complementary measures: Dice similarity coefficient (Dice) and the Hausdorff distance at the 95th percentile (HD95). Furthermore, a noninferiority test was performed comparing the model with the human raters. The null hypothesis (H0) was that the model performs worse than human raters by at least Δ = 0.055 Dice, a difference that is considered clinically negligible. Results: The average processing time per frame was 19.80 ± 5.08 seconds for human operators, compared with 0.03404 seconds ± 0.01806 seconds for the AI model running on a standard consumer-grade laptop. This represents a difference of nearly three orders of magnitude (a difference that could be quantitatively described as 580 times faster). Agreement between human raters was very high, with median Dice 0.959 (95% confidence interval, 0.958-0.960). Agreement between the model and each rater was slightly lower, with a median Dice of approximately 0.907 (95% confidence interval, 0.904-0.909). Human raters had median HD95 values of <5 pixels, reflecting very small boundary differences. The model-vs-rater comparisons showed somewhat higher HD95 values, with medians or approximately 8 to 10 pixels, but still within a clinically acceptable range given the resolution of the images. The Wilcoxon paired test rejected the null hypothesis H0 (P = .004169), showing that the model is not inferior to human raters within this clinically acceptable margin. Conclusions: Our study demonstrates an amazing time efficiency of the entire AI segmentation process, with a precision quite comparable with the human researchers' assessment. Our findings, in perspective, support the clinical introduction of ultrasound AI JVP waveform assessment in a variety of potentially interested medical specialties, including cardiology, critical care, neurosciences, and vascular surgery.
No takes yet. Share an insight, caveat, or question.
Zamboni et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: