Answers are grounded in this paper and cite their sources.
In this paper, a novel load-network solution to implement the transmission-line inverse Class F power amplifier for WCDMA active antenna array applications is presented. The theoretical analysis is based on an analytical derivation of the optimum load-network parameters to control the second and third harmonic at the device output including the device output parasitic shunt capacitance and series inductance. For an inverse Class F power amplifier based on a Nitronex GaN HEMT NPTB00004 with hybrid microstrip implementation, the simulated output power of 37 dBm and power-added efficiency of more than 70% are achieved at a supply voltage of 25 V in a frequency bandwidth of 2.11 to 2.17 GHz. The test board with implemented inverse Class F GaN HEMT power amplifier has been measured and high-performance results with drain efficiencies of about 80% and higher were achieved across the wide ranges of bias supply voltages and operating frequencies.
No takes yet. Share an insight, caveat, or question.
Andrei Grebennikov (2009) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: