March 14, 1992BMJ266 citationsOpen Access

Extended fetal echocardiographic examination for detecting cardiac malformations in low risk pregnancies.

RAR. AchironJGJoram GlaserIGIlana Gelernter

Structured PICO

Does extended fetal echocardiography improve the detection of cardiac malformations compared to the standard four chamber view in low risk pregnancies?

P
Population
5,400 fetuses in low risk pregnancies between 18 and 24 weeks' gestation (mean 21 weeks)
I
Intervention
Extended fetal echocardiography (four chamber view plus visualisation of the left ventricular outflow tract, the right ventricular outflow tract, and the main pulmonary artery and its branches)
C
Comparator
Standard four chamber view alone
O
Outcome
Detection of cardiac abnormality before and after birth

Extended fetal echocardiography significantly improves the prenatal detection of major cardiac malformations in low-risk pregnancies compared to the standard four-chamber view.

Abstract

OBJECTIVE: To improve the rate of prenatal detection of cardiac malformations in a low risk population. DESIGN: Comparison of extended fetal echocardiography with the standard four chamber view in detecting abnormalities. Extended echocardiography comprised the four chamber view and visualisation of the left ventricular outflow tract, the right ventricular outflow tract, and the main pulmonary artery and its branches. In cases with abnormal results complete echocardiographic studies were performed by a paediatric cardiologist using M mode, Doppler, and colour flow mapping techniques. SETTING: Obstetric ultrasonographic unit at Shaare-Zedek Medical Centre, Jerusalem. SUBJECTS: 5400 fetuses in low risk pregnancies between 18 and 24 weeks' gestation (mean 21 weeks); 53 were lost to follow up. MAIN OUTCOME MEASURES: Detection of abnormality before and after birth. RESULTS: During the study 23 infants (0.4%) were born with cardiac abnormalities, 21 of whom had major structural and functional heart disease. 18 fetuses had heart disease diagnosed prenatally, 11 by the four chamber view alone (sensitivity 48%) and a further seven by extended echocardiography (sensitivity 78%). Five fetal cardiac defects were missed prenatally (false negative rate 22%). These included coarctation of aorta, persistent truncus arteriosus, tetralogy of Fallot, ventricular septal defect, and pulmonic stenosis. Only one false positive diagnosis (coarctation of aorta) was made (specificity 99.9%, false positive rate 0.1%). The abnormality was correctly identified in 17 out of 18 cases. CONCLUSIONS: The extended fetal heart examination detected 86% (18/21) of major abnormalities in a low risk population. The examination should be incorporated into routine prenatal ultrasonographic investigations.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Achiron et al. (1992) studied this question.

synapsesocial.com/papers/6a1c4834923c8e1e6e9cd60ahttps://doi.org/10.1136/bmj.304.6828.671
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Fetal echocardiography: experience and reason1986 · 4 citations
  2. 2Clinical impact of first and early second trimester fetal echocardiography on high risk pregnancies2004 · 113 citations
  3. 3Fetal Echocardiography as a Screening Method for Detection of Congenital Heart Disease2020
  4. 4Reliability of Early Fetal Echocardiography for Congenital Heart Disease Detection: A Preliminary Experience and Outcome Analysis of 102 Fetuses to Demonstrate the Value of a Clinical Flow-Chart Designed for At-Risk Pregnancy Management2016 · 5 citations
  5. 5Early fetal echocardiography: Experience of a tertiary diagnostic service2015 · 18 citations