Key result
Remote monitoring of therapeutic cardiac devices required 9.4-13.5 minutes of staff time per transmission, compared to 37.8-51.0 minutes for an in-person clinic visit.
Why the study?
The growing number of patients with cardiac implantable electronic devices creates substantial clinic workload, requiring characterization of workflow and quantification of staff time requirements.
Observational
Yes
Managing CIED patients requires significant staff time, with in-person visits taking roughly 40-50 minutes and remote transmissions taking 9-13 minutes, highlighting the need for workflow efficiency.
Answers are grounded in this paper and cite their sources.
Remote monitoring may reduce staff time for CIED follow-up; hypothesis-generating for workflow optimization in prospective studies.
BACKGROUND The number of patients with cardiac implantable electronic device (CIED) is increasing, creating a substantial workload for device clinics. OBJECTIVE This study aims to characterize the workflow and quantify clinic staff time requirements for managing patients with CIEDs. METHODS A time and motion workflow evaluation was performed in 11 US and European CIEDs clinics. Workflow tasks were repeatedly timed during 1 business week of observation at each clinic; these observations included all device models and manufacturers. The mean cumulative staff time required to review a remote device transmission and an in-person clinic visit were calculated, including all necessary clinical and administrative tasks. The annual staff time to manage a patient with a CIED was modeled using CIED transmission volumes, clinical guidelines, and the published literature. RESULTS A total of 276 in-person clinic visits and 2173 remote monitoring activities were observed. Mean staff time required per remote transmission ranged from 9.4 to 13.5 minutes for therapeutic devices (pacemaker, implantable cardioverter-defibrillator, and cardiac resynchronization therapy) and from 11.3 to 12.9 minutes for diagnostic devices such as insertable cardiac monitors (ICMs). Mean staff time per in-person visit ranged from 37.8 to 51.0 and from 39.9 to 45.8 minutes for therapeutic devices and ICMs, respectively. Including all remote and in-person follow-ups, the estimated annual time to manage a patient with a CIED ranged from 1.6 to 2.4 hours for therapeutic devices and from 7.7 to 9.3 hours for ICMs. CONCLUSIONS The CIED patient management workflow is complex and requires significant staff time. Understanding process steps and time requirements informs the implementation of efficiency improvements, including remote solutions. Future research should examine heterogeneity in patient management processes to identify the most efficient workflow. CLINICALTRIAL
No takes yet. Share an insight, caveat, or question.
Seiler et al. (2021) conducted an observational in Cardiac implantable electronic device (CIED) management. Remote device transmission review vs. In-person clinic visit was evaluated on Mean cumulative staff time required to review a remote device transmission and an in-person clinic visit. Remote monitoring of therapeutic cardiac devices required 9.4-13.5 minutes of staff time per transmission, compared to 37.8-51.0 minutes for an in-person clinic visit.
Synapse has enriched 10 related papers. Consider them for comparative context: