Why the study?
Patients with hypertrophic cardiomyopathy have an increased prevalence of AF, and left atrium remodeling is strongly correlated with AF risk, prompting assessment of LA electrocardiographic and echocardiographic parameters for predicting incident AF.
Do left atrium electrocardiographic and echocardiographic parameters predict incident atrial fibrillation in patients with hypertrophic cardiomyopathy?
Cohort (n=126)
No
Do left atrium electrocardiographic and echocardiographic parameters predict incident atrial fibrillation in patients with hypertrophic cardiomyopathy?
Effect estimate: HR 4.24 (95% CI 1.84-9.75)
p-value: p=0.038
Left atrium booster pump function and P wave dispersion are independent predictors of incident atrial fibrillation in patients with hypertrophic cardiomyopathy, offering better risk stratification than conventional LA size assessment.
Background Patients with hypertrophic cardiomyopathy (HCM) have an increased prevalence of atrial fibrillation (AF) compared to the general population, and left atrium (LA) remodeling is strongly correlated with the risk of AF. This prospective, monocentric study aimed to assess the role of LA electrocardiographic and echocardiographic (structural and functional) parameters in predicting the risk for incident AF in patients with HCM. Methods and Results The study population consisted of 126 HCM patients in sinus rhythm (52.6 ± 16.2 years, 54 men), 118 of them without documented AF. During a median follow-up of 56 (7–124) months, 39 (30.9%) developed a new episode of AF. Multivariable analysis showed that LA booster pump function (assessed by ASr, HR = 4.24, CI = 1.84–9.75, and p = 0.038) and electrical dispersion (assessed by P wave dispersion – Pd, HR = 1.044, CI = 1.029–1.058, and p = 0.001), and not structural parameters (LA diameter, LA volume) were independent predictors of incident AF. Seventy-two patients had a LA diameter < 45 mm, and 16 of them (22.2%) had an AF episode during follow-up. In this subgroup, only Pd emerged as an independent predictor for incident AF (HR = 1.105, CI = 1.059–1.154, and p = 0.002), with good accuracy (AUC = 0.89). Conclusion Left atrium booster pump function (ASr) and electrical dispersion (Pd) are related to the risk of incident AF in HCM patients. These parameters can provide further stratification of the risk for AF in this setting, including in patients considered at lower risk for AF based on the conventional assessment of LA size.
No takes yet. Share an insight, caveat, or question.
Mandeş et al. (2022) conducted a cohort in Hypertrophic cardiomyopathy (n=126). Left atrium electrocardiographic and echocardiographic parameters was evaluated on Incident atrial fibrillation (HR 4.24, 95% CI 1.84-9.75, p=0.038).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: