This is the authors' abstract. We don't add key points for this paper.
Optical coherence microscopy (OCM) is demonstrated with a high-speed, broadband, reflective-grating phase modulator and a femtosecond Ti:Al2O3 laser. The novel system design permits high-resolution OCM imaging in a new operating regime in which a short coherence gate is used to relax the requirement for high-numerical-aperture confocal axial sectioning. In vivo cellular imaging is demonstrated in the Xenopus laevis tadpole and in human skin with a 3-microm coherence gate and a 30-microm confocal gate. The ability to achieve cellular imaging with a lower numerical aperture should facilitate the development of miniaturized probes for in vivo imaging applications.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Aguirre et al. (2003) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: