Key result
PPG wearables show poor agreement with ECG for measuring HRV during ambulatory movement.
Why the study?
Heart rate and heart rate variability are key measures in psychophysiological studies, but photoplethysmography-based wearables pose critical validity concerns.
Do PPG wearables accurately measure HR and HRV compared to criterion ECG in healthy participants across resting and ambulatory conditions?
Observational (n=40)
No
Do PPG wearables accurately measure HR and HRV compared to criterion ECG in healthy participants across resting and ambulatory conditions?
PPG-based wearables, including research-grade devices, have limited validity for measuring heart rate variability in non-resting conditions involving movement.
Answers are grounded in this paper and cite their sources.
PPG wearables warrant caution for HRV amid movement; leaves open their role for ambulatory HR monitoring.
Heart rate (HR) and heart rate variability (HRV) are two key measures with significant relevance in psychophysiological studies, and their measurement has become more convenient due to advances in wearable technology. However, photoplethysmography (PPG)-based wearables pose critical validity concerns. In this study, we validated four PPG wearables: three consumer-grade devices (Kyto2935, Schone Rhythm 24, and HeartMath Inner Balance Bluetooth) and one research-grade device (Empatica EmbracePlus, successor to the widely-used but discontinued Empatica E4). All devices were worn simultaneously by 40 healthy participants who underwent conditions commonly used in laboratory research (seated rest, arithmetic task, recovery, slow-paced breathing, a neuropsychological task, posture manipulation by standing up) and encountered in ambulatory-like settings (slow walking and stationary biking), compared against a criterion electrocardiography device, the Vrije Universiteit Ambulatory Monitoring System (VU-AMS). We determined the signal quality, the linear strength through regression analysis, the bias through Bland-Altman analysis, and the measurement error through mean arctangent absolute percentage error for each condition against the criterion device. We found that the research-grade device did not outperform the consumer-grade devices in laboratory conditions. It also showed low agreement with the ECG in ambulatory-like conditions. In general, devices captured HR more accurately than HRV. Finally, conditions that deviated from baseline settings and involved slight to high movement, negatively impacted the agreement between PPG devices and the criterion. We conclude that PPG devices, even those advertised and designed for research purposes, may pose validity concerns for HRV measurement in conditions other than those similar to resting states.
No takes yet. Share an insight, caveat, or question.
Sinichi et al. (2025) conducted an observational in Healthy participants (n=40). Four PPG wearables (Kyto2935, Schone Rhythm 24, HeartMath Inner Balance Bluetooth, Empatica EmbracePlus) vs. Criterion ECG device (VU-AMS) was evaluated on Agreement of HR and HRV measurements (signal quality, MAAPE, regression, Bland-Altman bias) between PPG devices and criterion ECG. Four PPG wearables, including a research-grade device, showed low agreement with criterion ECG for HRV measurement in ambulatory-like conditions involving movement, though they captured HR more accurately.