Key result
The occurrence of an electrical storm independently increased the risk of death (HR 1.93) in patients after myocardial infarction with an implanted ICD for secondary prevention.
Why the study?
Does the occurrence of an electrical storm increase mortality in patients after myocardial infarction with an implanted ICD for secondary prevention?
Cohort (n=97)
No
Does the occurrence of an electrical storm increase mortality in patients after myocardial infarction with an implanted ICD for secondary prevention?
Effect estimate: HR 1.93
Absolute Event Rate: 50% vs 30%
p-value: p=<0.001
Electrical storm is a relatively common phenomenon in post-MI patients with an ICD for secondary prevention and serves as an independent predictor of long-term mortality.
Electrical storm signals higher mortality risk in post-MI secondary-prevention ICD patients; leaves open whether targeted interventions improve survival.
The aim of our study was to determine the risk factors for electrical storm (ES) and to assess the impact of ES on the long-term prognosis in patients after myocardial infarction (MI) with an implantable cardioverter-defibrillator (ICD) for secondary prevention of sudden cardiac death (SCD). Material and methods: We retrospectively analyzed 416 patients with coronary artery disease after MI who had an implanted ICD for secondary prevention of SCD. Fifty (12%) patients had one or more incidents of an electrical storm -the ES (+) group. We matched the reference group of 47 patients from 366 ES (-) patients. Results: We analyzed 3,408 episodes of ventricular arrhythmias: 3,148 ventricular tachyarrhythmic episodes in the ES (+) group (including 187 episodes of ES) and 260 in the ES (-) group. Multivariate logistic regression showed that inferior wall MI (RR = 3.98, 95% CI: 1.52-10.41) and the absence of coronary revascularization (RR = 2.92, 95% CI: 1.18-7.21) were independent predictors of ES (p = 0.0014). During 6-year observation of 97 patients, there were 39 (40%) deaths: 25 (50%) subjects in the ES (+) group and 14 (30%) in the ES (-) group (p = 0.036). Independent predictors of death were: the occurrence of ES (HR = 1.93), older age (HR = 1.06), and lower left ventricular ejection fraction (HR = 0.95) (for all p < 0.001). Conclusions: Electrical storm in patients after MI with ICD for secondary prevention is a relatively common phenomenon and has a negative prognostic significance. Myocardial infarction of the inferior wall and the absence of coronary revascularization are predisposing factors for the occurrence of an ES.
No takes yet. Share an insight, caveat, or question.
Kwaśniewski et al. (2016) conducted a cohort in Coronary artery disease after myocardial infarction with an implanted ICD for secondary prevention of sudden cardiac death (n=97). Electrical storm vs. No electrical storm was evaluated on Death (HR 1.93, p=<0.001). The occurrence of an electrical storm independently increased the risk of death (HR 1.93) in patients after myocardial infarction with an implanted ICD for secondary prevention.