Answers are grounded in this paper and cite their sources.
A multiple PWM GTO line-side converter with low switched frequency has been developed for industrial uses needing both higher capacity and performance. The multiple converter is composed of two GTO converter units parallel connected through an interphase reactor. The switching frequency of the GTO thyristors in the multiple converter can be reduced to a quarter of that in the single converter. It is verified by simulations and experiments with a 2750 kVA GTO converter and inverter system with 500 Hz switching frequency that the system has: (1) a unity power factor, (2) reduced harmonics, (3) bidirectional power flow, and (4) speed regulatory performance equal to that of an advanced cycloconverter drive system.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
No takes yet. Share an insight, caveat, or question.
Sukegawa et al. (2002) studied this question.