Why the study?
Can time domain echo patterns differentiate between normal arterial walls and various types of atherosclerotic plaques in vitro?
Can time domain echo patterns differentiate between normal arterial walls and various types of atherosclerotic plaques in vitro?
Time domain echo patterns can quantitatively differentiate fatty plaques from other atherosclerotic plaque types and normal arterial walls in vitro.
Time-domain echo may differentiate fatty plaques in vitro; hypothesis-generating from animal data only.
The aim of this study in vitro of human fresh specimens was to quantitatively evaluate the contribution of the aqueous phase-intima interface (the first 400 msec of the reflected signal) in normal and atherosclerotic arterial walls. Seventy-five samples were studied, 15 normal, 15 fatty, 15 fibrofatty, 15 fibrous, and 15 calcific. A broadband transducer (4 to 14 MHz) was used. The aqueous phase-intima reflection (expressed in dB, mean +/- SD) was lowest in the fatty plaques (-35.3 +/- 2.5), differing in a highly significant way from that in all other groups: normal (-13.2 +/- 8.8), fibrofatty (-20.4 +/- 8.3), fibrous (-13.0 +/- 9.7), calcific (-5.9 +/- 3.4). The echo coming from the intima-media transition was of relatively low amplitude in normal and in fatty samples; typically, strong reflections from the intima-media transitions were present in the other pathologic subsets. In conclusion, the time domain echo pattern of the arterial wall may provide a useful clue to the structure of the plaque.
No takes yet. Share an insight, caveat, or question.
Picano et al. (1988) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: