Key result
A non-invasive ECG measurement method using three electrodes for lead II in mice provided stable and reproducible recordings, successfully detecting significant differences in heart rate between Balb/c and FVB strains.
Why the study?
Is a non-invasive 3-electrode lead II method accurate and reproducible for measuring ECG parameters in anesthetized mice?
Is a non-invasive 3-electrode lead II method accurate and reproducible for measuring ECG parameters in anesthetized mice?
A non-invasive 3-electrode lead II method provides an accurate, reproducible, and rapid alternative to radiotelemetry for measuring ECG parameters in anesthetized mice.
Answers are grounded in this paper and cite their sources.
Offers rapid non-invasive ECG alternative in anesthetized mice; leaves open conscious-model validation and clinical translation.
Electrocardiogram measures the electric impulses generated by the heart during its cycle. Recently genome-wide association studies on electrocardiogram traits revealed many relevant genetic loci. Therefore, these findings need to be validated and investigated to determine the underlying mechanisms using mouse models. Invasive radiotelemetry has been widely used to record the electrocardiogram in mice because it has several advantages over non-invasive measurements. However, radiotelemetry is expensive and requires complicated surgery. On the other hand, a non-invasive method using 3 electrodes (one for earth) for lead II is easy to establish and allows for rapid measurement. In this study, eleven mice were measured with this non-invasive method and no statistical difference among them was found in any ECG measurements. In addition, repeat measurement in the same mouse was performed in 9 sets of experiment and the results indicated that non-invasive method was reliable for reproducibility. Further it was shown that measurements for 1, 5, 10, and 15 minutes were not different so that a short recording such as 5 minutes was enough to estimate the ECG values including heart rate. Further this method was validated by measuring the ECG of Balb/c and FVB that were previously shown to differ in ECG values by radiotelemetry. Significant differences were found in heart rate, PR interval and corrected QT interval between these mouse strains. This study partially proved that non-invasive method also could provide the accuracy and reproducibility. Based on these results, the non-invasive ECG recordings of lead II is recommended as a useful method for quick test in mouse model.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2015) studied Healthy mice (ECG validation) (n=24). Non-invasive ECG measurement (lead II) vs. Balb/c vs FVB strains was evaluated on Heart rate (BPM) (p=5.67E-06). A non-invasive ECG measurement method using three electrodes for lead II in mice provided stable and reproducible recordings, successfully detecting significant differences in heart rate between Balb/c and FVB strains.