Key result
Sirolimus-eluting stents significantly reduced the 3-year rate of major adverse cardiovascular events (HR 0.68) compared to bare metal stents in patients with acute myocardial infarction.
Why the study?
Does primary PCI using sirolimus-eluting stents reduce major adverse cardiovascular events at 3 years compared to bare metal stents in patients with acute myocardial infarction?
Cohort (n=272)
No
Does primary PCI using sirolimus-eluting stents reduce major adverse cardiovascular events at 3 years compared to bare metal stents in patients with acute myocardial infarction?
Effect estimate: HR 0.68 (95% CI 0.50-0.92)
Absolute Event Rate: 20.3% vs 33.1%
p-value: p=0.01
In patients with acute myocardial infarction undergoing primary PCI, sirolimus-eluting stents significantly reduced 3-year major adverse cardiovascular events compared to bare metal stents, driven primarily by a reduction in target vessel revascularization without an increase in stent thrombosis.
May inform stent selection in AMI PCI; leaves open confirmation via randomized trials before practice change.
BACKGROUND: The long-term safety and efficacy of drug-eluting stents for patients with acute myocardial infarction (AMI) remain controversial. METHODS AND RESULTS: A total of 143 consecutive patients who presented between August 2004 and July 2006 with AMI and who underwent primary percutaneous coronary intervention (PCI) using sirolimus-eluting stents (SES), were compared with a historical control cohort of 129 consecutive patients who presented between August 2002 and July 2004 and who underwent primary PCI using bare metal stents (BMS). The rate of major adverse cardiovascular events at 3 years was significantly lower in the SES group than in the BMS group (20.3% vs. 33.1%, respectively; P=0.01). This reduction was mainly driven by a decrease in the rate of target vessel revascularization (12.3% vs. 22.4%, respectively; P=0.02). There was no significant difference in the rate of cardiovascular death (4.5% vs. 5.7%, respectively; P=0.67), non-fatal myocardial infarction (4.5% vs. 9.2%, respectively; P=0.16), coronary artery bypass grafting (2.3% vs. 2.5%, respectively; P=0.93), stroke (2.4% vs. 0.8%, respectively; P=0.35), and stent thrombosis (2.9% vs. 2.3%, respectively; P=0.80) between the 2 groups. CONCLUSIONS: SES can be used safely and effectively in patients with AMI.
No takes yet. Share an insight, caveat, or question.
Ejiri et al. (2011) conducted a cohort in Acute myocardial infarction (n=272). Sirolimus-eluting stents vs. Bare metal stents was evaluated on Major adverse cardiovascular events (MACE) at 3 years (HR 0.68, 95% CI 0.50-0.92, p=0.01). Sirolimus-eluting stents significantly reduced the 3-year rate of major adverse cardiovascular events (HR 0.68) compared to bare metal stents in patients with acute myocardial infarction.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: