Key result
An automatic system using a support vector machine classifier achieved 97.7% accuracy in discriminating atrial fibrillation types from intracardiac electrograms using seven features.
Why the study?
Does an automatic SVM-based system improve the classification accuracy of atrial fibrillation patterns from intracardiac electrograms compared to traditional classifiers?
Does an automatic SVM-based system improve the classification accuracy of atrial fibrillation patterns from intracardiac electrograms compared to traditional classifiers?
An automatic SVM-based system accurately classifies atrial fibrillation patterns from intracardiac electrograms, outperforming traditional maximum likelihood classifiers even with limited training data.
Answers are grounded in this paper and cite their sources.
May support automated AF classification in EP labs; leaves open prospective validation before clinical adoption.
This paper presents an automatic system for the analysis and classification of atrial fibrillation (AF) patterns from bipolar intracardiac signals. The system is made up of: 1) a feature-extraction module that defines and extracts a set of measures potentially useful for characterizing AF types on the basis of their degree of organization; 2) a feature-selection module (based on the Jeffries-Matusita distance and a branch and bound search algorithm) identifying the best subset of features for discriminating different AF types; and 3) a support vector machine technique-based classification module that automatically discriminates the AF types according to the Wells' criteria. The automatic system was applied on 100 intracardiac AF signal strips and on a selection of 11 representative features, demonstrating: a) the possibility to properly identify the most significant features for the discrimination of AF types; b) higher accuracy (97.7% using the seven most informative features) than the traditional maximum likelihood classifier; and c) effectiveness in AF classification also with few training samples (accuracy = 88.3% with only five training signals). Finally, the system identifies a combination of indices characterizing changes of morphology of atrial activation waves and perturbation of the isoelectric line as the most effective in separating the AF types.
No takes yet. Share an insight, caveat, or question.
Nollo et al. (2008) studied Atrial fibrillation (n=100). Automatic system with support vector machine classification vs. Traditional maximum likelihood classifier was evaluated on Accuracy of atrial fibrillation type classification. An automatic system using a support vector machine classifier achieved 97.7% accuracy in discriminating atrial fibrillation types from intracardiac electrograms using seven features.