Why the study?
Does facial photoplethysmography using a smartphone application accurately detect atrial fibrillation in cardiology inpatients compared to 12-lead ECG?
Does facial photoplethysmography using a smartphone application accurately detect atrial fibrillation in cardiology inpatients compared to 12-lead ECG?
Contact-free facial photoplethysmography using a smartphone camera is highly sensitive and specific for detecting atrial fibrillation, offering a convenient potential tool for community screening.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for contact-free smartphone AF screening; prospective validation needed before clinical adoption.
BACKGROUND: We aimed to evaluate a novel method of atrial fibrillation (AF) screening using an iPhone camera to detect and analyze photoplethysmographic signals from the face without physical contact by extracting subtle beat-to-beat variations of skin color that reflect the cardiac pulsatile signal. METHODS AND RESULTS: Patients admitted to the cardiology ward of the hospital for clinical reasons were recruited. Simultaneous facial and fingertip photoplethysmographic measurements were obtained from 217 hospital inpatients (mean age, 70.3±13.9 years; 71.4% men) facing the front camera and with an index finger covering the back camera of 2 independent iPhones before a 12-lead ECG was recorded. Backdrop and background light intensity was monitored during signal acquisition. Three successive 20-second (total, 60 seconds) recordings were acquired per patient and analyzed for heart rate regularity by Cardiio Rhythm (Cardiio Inc, Cambridge, MA) smartphone application. Pulse irregularity in ≥1 photoplethysmographic readings or 3 uninterpretable photoplethysmographic readings were considered a positive AF screening result. AF was present on 12-lead ECG in 34.6% (n=75/217) patients. The Cardiio Rhythm facial photoplethysmographic application demonstrated high sensitivity (95%; 95% confidence interval, 87%-98%) and specificity (96%; 95% confidence interval, 91%-98%) in discriminating AF from sinus rhythm compared with 12-lead ECG. The positive and negative predictive values were 92% (95% confidence interval, 84%-96%) and 97% (95% confidence interval, 93%-99%), respectively. CONCLUSIONS: Detection of a facial photoplethysmographic signal to determine pulse irregularity attributable to AF is feasible. The Cardiio Rhythm smartphone application showed high sensitivity and specificity, with low negative likelihood ratio for AF from facial photoplethysmographic signals. The convenience of a contact-free approach is attractive for community screening and has the potential to be useful for distant AF screening.
No takes yet. Share an insight, caveat, or question.
Yan et al. (2018) studied this question.