Why the study?
The study was conducted to account for dissection flap motion and assess its effect on flow and hemodynamics in acute type B aortic dissection.
Does a fluid-structure interaction model accounting for flap motion alter the predicted hemodynamics compared to a rigid wall model in acute type B aortic dissection?
Does a fluid-structure interaction model accounting for flap motion alter the predicted hemodynamics compared to a rigid wall model in acute type B aortic dissection?
A fully coupled fluid-structure interaction model demonstrates that physiological flap motion in acute type B aortic dissection significantly alters flow distribution, wall shear stress, and pressure compared to rigid models.
Answers are grounded in this paper and cite their sources.
FSI modeling of flap motion warrants consideration in dissection simulations; leaves open validation against patient outcomes.
A monolithic, fully coupled fluid‐structure interaction (FSI) computational framework was developed to account for dissection flap motion in acute type B aortic dissection (TBAD). Analysis of results included wall deformation, pressure, flow, wall shear stress (WSS), von Mises stress and comparison of hemodynamics between rigid wall and FSI models. Our FSI model mimicked realistic wall deformation that resulted in maximum compression of the distal true lumen (TL) by 21.4%. The substantial movement of intimal flap mostly affected flow conditions in the false lumen (FL). Flap motion facilitated more flow entering the FL at peak systole, with the TL to FL flow split changing from 88:12 in the rigid model to 83:17 in the FSI model. There was more disturbed flow in the FL during systole (5.8% FSI vs 5.2% rigid) and diastole (13.5% FSI vs 9.8% rigid), via a λ 2 ‐criterion. The flap‐induced disturbed flow near the tears in the FSI model caused an increase of local WSS by up to 70.0% during diastole. This resulted in a significant reduction in the size of low time‐averaged WSS (TAWSS) regions in the FL (113.11 cm 2 FSI vs 177.44 cm 2 rigid). Moreover, the FSI model predicted lower systolic pressure, higher diastolic pressure, and hence lower pulse pressure. Our results provided new insights into the possible impact of flap motion on flow in aortic dissections, which are particularly important when evaluating hemodynamics of acute TBAD. Novelty Statement Our monolithic fully coupled FSI computational framework is able to reproduce experimentally measured range of flap deformation in aortic dissection, thereby providing novel insights into the influence of physiological flap motion on the flow and pressure distributions. The drastic flap movement increases the flow resistance in the true lumen and causes more disturbed flow in the false lumen, as visualized through the λ 2 criterion. The flap‐induced luminal pressure is dampened, thereby affecting pressure measures, which may serve as potential prognostic indicators for late complications in acute uncomplicated TBAD patients.