Key result
CoV2 preS dTM-AS03 boosters elicited significantly higher neutralizing antibody titers against D614G and B.1.351 variants compared to primary vaccination, with an anti-D614G GMT ratio of 2.16 for the monovalent D614 booster.
Why the study?
Booster vaccines providing protection against emergent SARS-CoV-2 variants are needed.
Does a CoV2 preS dTM-AS03 booster improve neutralizing antibody titers against SARS-CoV-2 variants in adults primed with authorized COVID-19 vaccines?
RCT (n=2,602)
Open-label (cohort 1) and modified double-blind (cohort 2)
1:1 or 9:1 in cohort 2
Yes
Does a CoV2 preS dTM-AS03 booster improve neutralizing antibody titers against SARS-CoV-2 variants in adults primed with authorized COVID-19 vaccines?
Effect estimate: GMT ratio 2.16 (95% CI 1.69-2.75)
Absolute Event Rate: 7894% vs 3658%
CoV2 preS dTM-AS03 boosters elicited robust neutralizing antibodies against multiple SARS-CoV-2 variants with acceptable safety, regardless of the primary vaccine series received.
Boosters enhance variant neutralization in primed adults; extends RCT evidence for CoV2 preS dTM-AS03 across primary series.
Background Booster vaccines providing protection against emergent SARS-CoV-2 variants are needed. In an international phase 3 study, we evaluated booster vaccines containing prototype (D614) and/or Beta (B.1.351) variant recombinant spike proteins and AS03 adjuvant (CoV2 preS dTM-AS03). Methods Adults, primed 4–10 months earlier with mRNA (BNT162b2, mRNA-1273]), adenovirus-vectored (Ad26.CoV2.S, ChAdOx1nCoV-19) or adjuvanted protein (CoV2 preS dTM-AS03 [D614]) vaccines and stratified by age (18-55 and ≥56 years), were boosted with monovalent (MV) D614 (5μg, n=1285), MV (B.1351) (5μg, n=707) or bivalent (BiV) (2.5μg D614 plus 2.5μg B.1.351, n=625) CoV2 preS dTM-AS03. SARS-CoV-2-naïve adults (controls, n=479) received a primary series (two injections, 21 days apart) of CoV2 preS dTM-AS03 containing 10μg D614. Antibodies to D614G, B.1.351 and Omicron BA.2 and BA.1 variants were evaluated using validated pseudovirus (lentivirus) neutralization (PsVN) assay. D614G or B.1.351 PsVN titers 14 days (D15) post-booster were compared with pre-booster (D1) titers in BNT162b2-primed participants (18-55 years old) and controls (D36), for each booster formulation (co-primary objectives). Safety was evaluated throughout the trial. Results of a planned interim analysis are presented. Results Among BNT162b2-primed adults (18-55 years old), PsVN titers against D614G or B.1.351 were significantly higher post-booster than anti-D614G titers post-primary vaccination in controls, for all booster formulations, with an anti-D614G GMT ratio (98.3% CI) of 2.16 (1.69; 2.75) for MV(D614), an anti-B.1.351 ratio of 1.96 (1.54; 2.50) for MV (B.1.351) and anti-D614G and anti-B.1.351 ratios of 2.34 (1.84; 2.96) and 1.39 (1.09; 1.77), respectively, for BiV. All booster formulations elicited cross-neutralizing antibodies against Omicron BA.2 across vaccine priming subgroups and against Omicron BA.1 (evaluated in BNT162b2-primed participants). Similar patterns in antibody responses were observed for participants aged ≥56 years. No safety concerns were identified. Conclusion CoV2 preS dTM-AS03 boosters demonstrated acceptable safety and elicited robust neutralizing antibodies against multiple variants, regardless of priming vaccine. ClinicalTrials.gov NCT04762680 Funding Sanofi and federal funds from the Biomedical Advanced Research and Development Authority (BARDA), part of the office of the Administration for Strategic Preparedness and Response at the U.S. Department of Health and Human Services under Contract # HHSO100201600005I, and in collaboration with the U.S. Department of Defense Joint Program Executive Office for Chemical, Biological, Radiological and Nuclear Defense under Contract # W15QKN-16-9-1002.
No takes yet. Share an insight, caveat, or question.
Bruyn et al. (2022) conducted an RCT in COVID-19 (n=2,602). CoV2 preS dTM-AS03 booster (monovalent D614, monovalent B.1.351, or bivalent D614+B.1.351) vs. Primary series of CoV2 preS dTM-AS03 containing 10 µg D614 (control group) was evaluated on D614G PsVN GMT at day 15 post-booster compared to day 36 post-primary vaccination in controls (GMT ratio 2.16, 95% CI 1.69-2.75). CoV2 preS dTM-AS03 boosters elicited significantly higher neutralizing antibody titers against D614G and B.1.351 variants compared to primary vaccination, with an anti-D614G GMT ratio of 2.16 for the monovalent D614 booster.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: