Key result
An electronic health record-based predictive model successfully identified patients with incident atrial fibrillation across five countries, achieving an area under the curve ranging from 0.79 to 0.84.
Why the study?
The burden of atrial fibrillation on patients and healthcare systems warrants innovative screening strategies, prompting external validation of an electronic health record-based predictive model across multiple countries.
Does an electronic health record-based predictive model accurately identify patients with incident atrial fibrillation across different countries?
Cohort (n=3,494,969)
Yes
Does an electronic health record-based predictive model accurately identify patients with incident atrial fibrillation across different countries?
Answers are grounded in this paper and cite their sources.
An electronic health record-based predictive model demonstrated good discrimination for identifying incident atrial fibrillation across multiple international primary care databases, suggesting its potential utility for targeted AF screening.
BACKGROUND: Atrial fibrillation (AF) burden on patients and healthcare systems warrants innovative strategies for screening asymptomatic individuals. OBJECTIVE: We sought to externally validate a predictive model originally developed in a German population to detect unidentified incident AF utilising real-world primary healthcare databases from countries in Europe and Australia. METHODS: This retrospective cohort study used anonymized, longitudinal patient data from 5 country-level primary care databases, including Australia, Belgium, France, Germany, and the UK. The study eligibility included adult patients (≥45 years) with either an AF diagnosis (cases) or no diagnosis (controls) who had continuous enrolment in the respective database prior to the study period. Logistic regression was fitted to a binary response (yes/no) for AF diagnosis using pre-determined risk factors. RESULTS: AF patients were from Germany (n = 63,562), the UK (n = 42,652), France (n = 7,213), Australia (n = 2,753), and Belgium (n = 1,371). Cases were more likely to have hypertension or other cardiac conditions than controls in all validation datasets compared to the model development data. The area under the receiver operating characteristic (ROC) curve in the validation datasets ranged from 0.79 (Belgium) to 0.84 (Germany), comparable to the German study model, which had an area under the curve of 0.83. Most validation sets reported similar specificity at approximately 80% sensitivity, ranging from 67% (France) to 71% (United Kingdom). The positive predictive value (PPV) ranged from 2% (Belgium) to 16% (Germany), and the number needed to be screened was 50 in Belgium and 6 in Germany. The prevalence of AF varied widely between these datasets, which may be related to different coding practices. Low prevalence affected PPV, but not sensitivity, specificity, and ROC curves. CONCLUSIONS: AF risk prediction algorithms offer targeted ways to identify patients using electronic health records, which could improve screening number and the cost-effectiveness of AF screening if implemented in clinical practice.
No takes yet. Share an insight, caveat, or question.
Mokgokong et al. (2022) conducted a cohort in Atrial fibrillation (n=3,494,969). Electronic health record-based predictive model vs. No AF diagnosis (controls) was evaluated on Area under the receiver operating characteristic (ROC) curve (AUC). An electronic health record-based predictive model successfully identified patients with incident atrial fibrillation across five countries, achieving an area under the curve ranging from 0.79 to 0.84.
Synapse has enriched 10 related papers. Consider them for comparative context: