Key result
Multidetector computed tomography (MDCT) provides global left ventricular functional parameters that are interchangeable with those obtained by magnetic resonance imaging.
Why the study?
Does multidetector computed tomography provide comparable global left ventricular functional parameters to magnetic resonance imaging?
Meta-Analysis
Does multidetector computed tomography provide comparable global left ventricular functional parameters to magnetic resonance imaging?
Multidetector computed tomography provides comparable and interchangeable measurements of global left ventricular function compared to the reference standard MRI.
Answers are grounded in this paper and cite their sources.
MDCT offers a practical alternative to MRI for global LV function assessment when MRI is unavailable or contraindicated; confirms interchangeability via meta-analysis.
Cardiac morbidity and mortality are closely related to cardiac volumes and global left ventricular (LV) function, expressed as left ventricular ejection fraction. Accurate assessment of these parameters is required for the prediction of prognosis in individual patients as well as in entire cohorts. The current standard of reference for left ventricular function is analysis by short-axis magnetic resonance imaging. In recent years, major extensive technological improvements have been achieved in computed tomography. The most marked development has been the introduction of the multidetector CT (MDCT), which has significantly improved temporal and spatial resolutions. In order to assess the current status of MDCT for analysis of LV function, the current available literature on this subject was reviewed. The data presented in this review indicate that the global left ventricular functional parameters measured by contemporary multi-detector row systems combined with adequate reconstruction algorithms and post-processing tools show a narrow diagnostic window and are interchangeable with those obtained by MRI.
No takes yet. Share an insight, caveat, or question.
Vleuten et al. (2006) conducted a meta-analysis in Assessment of global left ventricular function. Multidetector computed tomography (MDCT) vs. Magnetic resonance imaging (MRI) was evaluated on Global left ventricular functional parameters. Multidetector computed tomography (MDCT) provides global left ventricular functional parameters that are interchangeable with those obtained by magnetic resonance imaging.
Synapse has enriched 10 related papers. Consider them for comparative context: