Key result
Reliable detection of atrial fibrillation recurrence required higher intermittent rhythm monitoring frequencies (≥12 24-hour, ≥6 7-day, ≥4 14-day, or ≥3 30-day IRMs per year) than currently recommended.
Why the study?
What is the necessary intermittent rhythm monitoring frequency to reliably detect atrial fibrillation recurrence?
Observational (n=647)
No
What is the necessary intermittent rhythm monitoring frequency to reliably detect atrial fibrillation recurrence?
Current intermittent rhythm monitoring recommendations under-detect AF recurrence; shorter but more frequent monitoring strategies are more efficient.
Answers are grounded in this paper and cite their sources.
Current recommendations may under-detect AF recurrence; challenges guidelines and leaves open optimal strategies pending prospective validation.
OBJECTIVE: Although atrial fibrillation (AF) recurrence is unpredictable in terms of onset and duration, current intermittent rhythm monitoring (IRM) diagnostic modalities are short-termed and discontinuous. The aim of the present study was to investigate the necessary IRM frequency required to reliably detect recurrence of various AF recurrence patterns. METHODS: The rhythm histories of 647 patients (mean AF burden: 12 ± 22% of monitored time; 687 patient-years) with implantable continuous monitoring devices were reconstructed and analyzed. With the use of computationally intensive simulation, we evaluated the necessary IRM frequency to reliably detect AF recurrence of various AF phenotypes using IRM of various durations. RESULTS: The IRM frequency required for reliable AF detection depends on the amount and temporal aggregation of the AF recurrence (p<0.0001) as well as the duration of the IRM (p<0.001). Reliable detection (>95% sensitivity) of AF recurrence required higher IRM frequencies (>12 24-hour; >6 7-day; >4 14-day; >3 30-day IRM per year; p<0.0001) than currently recommended. Lower IRM frequencies will under-detect AF recurrence and introduce significant bias in the evaluation of therapeutic interventions. More frequent but of shorter duration, IRMs (24-hour) are significantly more time effective (sensitivity per monitored time) than a fewer number of longer IRM durations (p<0.0001). CONCLUSIONS: Reliable AF recurrence detection requires higher IRM frequencies than currently recommended. Current IRM frequency recommendations will fail to diagnose a significant proportion of patients. Shorter duration but more frequent IRM strategies are significantly more efficient than longer IRM durations. CLINICAL TRIAL REGISTRATION URL: Unique identifier: NCT00806689.
No takes yet. Share an insight, caveat, or question.
Charitos et al. (2014) conducted an observational in Atrial fibrillation (n=647). Intermittent rhythm monitoring (IRM) vs. Continuous monitoring (reference) was evaluated on IRM frequency required for reliable AF detection (≥95% sensitivity) (p=<0.0001). Reliable detection of atrial fibrillation recurrence required higher intermittent rhythm monitoring frequencies (≥12 24-hour, ≥6 7-day, ≥4 14-day, or ≥3 30-day IRMs per year) than currently recommended.
Synapse has enriched 10 related papers. Consider them for comparative context: