The paper presents a controller for a multi-fingered underactuated prosthetic hand based on tendon transmission. The control architecture is implemented in two subsequent and different phases. The first one is the pre-shaping of the hand, based on the grasp type is implemented by stand-alone motion controllers using PID position control algorithms. The desired force closure value is calculated according to the pre-shape measured tendons tension and to the grasping force. In the second phase, the involved fingers rapidly close around the object to perform a balanced distribution of the forces within the hand, as it happens in the human hand. The controller is thus able to perform successfully many stable grasps. An overview of the hardware architecture and the results in terms of grasping capabilities based on Cutkosky grasp taxonomy are also presented