Key result
In 8 normal volunteers, correction of short-axis cine MRI for basal-descent through-plane motion significantly improved the calculation and variability of regional wall thickening in basal segments.
Why the study?
Does correction for basal-descent through-plane motion improve the quantification of regional left ventricular wall thickening in short-axis cine MRI in normal volunteers?
Observational (n=8)
Does correction for basal-descent through-plane motion improve the quantification of regional left ventricular wall thickening in short-axis cine MRI in normal volunteers?
Correcting for basal-descent through-plane motion in short-axis cine MRI improves the quantification of regional left ventricular wall thickening in the most basal slices.
Answers are grounded in this paper and cite their sources.
Supports basal motion correction for research cine MRI; leaves open clinical impact in patients.
PURPOSE: To solve the problem of the basal descent movement in quantification of the regional left ventricular (LV) myocardial wall thickness (WTh) and wall thickening (%WT) in short-axis (SA) cine MRI for effectively assessing the regional wall motion of LV myocardium. MATERIALS AND METHODS: LV long-axis tagged MRI and SA cine MRI were performed to calculate the longitudinal translation and circumferential WTh of LV myocardium in eight normal volunteers. The new SA end-systolic thickness (EST) data were reconstructed from the original EST data, based on the quantified longitudinal translation of LV myocardium. RESULTS: The mean %WT of six segments in the basal section after correction was significantly different from that before correction in both intra- and inter-operator experiments. The polar map also showed the significant improvement of the variability of regional %WT and lack of quantification of %WT in the most basal SA slices after correction. CONCLUSION: The proposed technique demonstrated an important advantage to calculate the %WT in the most basal SA myocardial tissue, which was considered difficult to be achieved using cine MRI.
No takes yet. Share an insight, caveat, or question.
Chai et al. (2011) conducted an observational in Healthy volunteers (n=8). Correction of SA cine MRI for basal-descent through-plane motion vs. Uncorrected SA cine MRI was evaluated on Mean wall thickening (%WT) of six segments in the basal section. In 8 normal volunteers, correction of short-axis cine MRI for basal-descent through-plane motion significantly improved the calculation and variability of regional wall thickening in basal segments.
Synapse has enriched 10 related papers. Consider them for comparative context: