Key result
CMR-derived multiparametric models correlate modestly with brachial blood pressure measurements.
Why the study?
Standard outpatient cardiovascular MR procedures typically omit blood pressure measurements prior to image acquisition, despite blood pressure being a crucial factor affecting cardiac imaging assessments.
Does a CMR-derived blood pressure model accurately estimate brachial systolic and diastolic blood pressure in patients undergoing cardiovascular MR?
Observational (n=389)
Yes
Does a CMR-derived blood pressure model accurately estimate brachial systolic and diastolic blood pressure in patients undergoing cardiovascular MR?
Answers are grounded in this paper and cite their sources.
CMR-derived models can non-invasively estimate systolic and diastolic blood pressure, potentially allowing for retrospective BP estimation and improved assessment of load-dependent cardiac parameters.
AIMS: Blood pressure (BP) is a crucial factor in cardiovascular health and can affect cardiac imaging assessments. However, standard outpatient cardiovascular MR (CMR) imaging procedures do not typically include BP measurements prior to image acquisition. This study proposes that brachial systolic BP (SBP) and diastolic BP (DBP) can be modelled using patient characteristics and CMR data. METHODS: In this multicentre study, 57 patients from the PREFER-CMR registry and 163 patients from other registries were used as the derivation cohort. All subjects had their brachial SBP and DBP measured using a sphygmomanometer. Multivariate linear regression analysis was applied to predict brachial BP. The model was subsequently validated in a cohort of 169 healthy individuals. RESULTS: Age and left ventricular ejection fraction were associated with SBP. Aortic forward flow, body surface area and left ventricular mass index were associated with DBP. When applied to the validation cohort, the correlation coefficient between CMR-derived SBP and brachial SBP was (r=0.16, 95% CI 0.011 to 0.305, p=0.03), and CMR-derived DBP and brachial DBP was (r=0.27, 95% CI 0.122 to 0.403, p=0.0004). The area under the curve (AUC) for CMR-derived SBP to predict SBP>120 mmHg was 0.59, p=0.038. Moreover, CMR-derived DBP to predict DBP>80 mmHg had an AUC of 0.64, p=0.002. CONCLUSION: CMR-derived SBP and DBP models can estimate brachial SBP and DBP. Such models may allow efficient prospective collection, as well as retrospective estimation of BP, which should be incorporated into assessments due to its critical effect on load-dependent parameters.
No takes yet. Share an insight, caveat, or question.
Assadi et al. (2023) conducted an observational in Patients undergoing CMR evaluation and healthy individuals (n=389). CMR-derived blood pressure model vs. Brachial sphygmomanometer blood pressure measurement was evaluated on Correlation between CMR-derived diastolic blood pressure and brachial diastolic blood pressure in the validation cohort (r=0.27, 95% CI 0.122 to 0.403, p=0.0004). CMR-derived models incorporating patient demographics and imaging parameters modestly correlated with brachial diastolic blood pressure and systolic blood pressure.