Key result
Stereotactic radiosurgery using 35-40 Gy successfully achieved atrioventricular node ablation in swine models without exceeding known human normal tissue constraints to organs at risk.
Why the study?
Stereotactic radiosurgery delivered to cardiac arrhythmogenic foci is promising, but dosimetric evaluation of radiation dose to adjacent organs at risk during AV node ablation was needed.
Does stereotactic radiosurgery (35-40 Gy) for atrioventricular node ablation safely avoid exceeding normal tissue radiation constraints in a swine model?
Does stereotactic radiosurgery (35-40 Gy) for atrioventricular node ablation safely avoid exceeding normal tissue radiation constraints in a swine model?
Stereotactic radiosurgery at 35-40 Gy effectively ablates the AV node in a swine model without exceeding most known human normal tissue radiation constraints.
Supports preclinical feasibility in swine; leaves open human translation and safety trials.
Introduction Stereotactic radiosurgery (SRS) delivered to arrhythmogenic foci within the heart is a promising treatment modality. We dosimetrically evaluated the radiation dose to the organs at risk of four swine that were successfully treated with linear-accelerator-based SRS for atrioventricular (AV) node ablation. Materials and methods Single-chamber pacemakers were implanted in four large white breed swine. Cardiac computed tomography simulation scans were performed to localize the AV node and organs at risk. SRS (35-40 Gy) was delivered to the AV node, and the pigs were followed up with pacemaker interrogations. One-sample t-tests were used to evaluate Dmax of great vessels, esophagus, and chest wall as compared to known normal tissue constraints as per RTOG 0631 and AAPM Task Group 101. Results All pigs had disturbances of AV conduction with progressive transition into complete heart block. Macroscopic and microscopic evaluation showed fibrosis in the AV node but did not reveal any changes in non-nodal cardiac tissue or vessels. The mean Dmax±SD (p-value) of the chest wall (14.7±3.3 (0.02)), esophagus (10.7±1.1 (<0.01)) superior vena cava (3.3±4.1 (<0.01)), right pulmonary artery (16.1±6.4 (<0.01)), right pulmonary vein (15.7± 5 (<0.01)), left pulmonary artery (11.1±1.7 (<0.01)) and left pulmonary vein (14.1±2.6 (<0.01)), and the inferior vena cava (33.68±1.6 (0.026)) were significantly below the normal tissue constraint cutoffs. Mean±SD (p-value) of the ascending aorta (19.4±16.1 (0.12)) was not significantly different than normal tissue constraint cutoffs. One swine model treated at 40 Gy had small area of hotspot in the ascending aorta (40.65 (0.4 cc)). Conclusion We have demonstrated in our swine models that SRS using 35-40 Gy can be done without exceeding known human normal tissue constraints to the chest wall, esophagus, and great vessels.
No takes yet. Share an insight, caveat, or question.
Ramia et al. (2021) studied Cardiac arrhythmias (Atrioventricular node ablation) (n=4). Stereotactic radiosurgery (SRS) vs. Historical normal tissue constraints was evaluated on Maximal radiation dose (Dmax) to organs at risk compared to normal tissue constraints. Stereotactic radiosurgery using 35-40 Gy successfully achieved atrioventricular node ablation in swine models without exceeding known human normal tissue constraints to organs at risk.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: