Key result
The EQ-5D and 15D instruments yielded significantly different baseline HRQoL scores (0.795 vs 0.859; P<0.001) and showed poor agreement in patients undergoing elective CABG.
Why the study?
Do the EQ-5D and 15D instruments perform differently in assessing health-related quality of life in patients undergoing elective CABG?
Cohort (n=182)
No
Do the EQ-5D and 15D instruments perform differently in assessing health-related quality of life in patients undergoing elective CABG?
Absolute Event Rate: 0.795% vs 0.859%
p-value: p=<0.001
The EQ-5D and 15D instruments are not interchangeable for assessing HRQoL in CABG patients, as they yield significantly different estimates of QALYs gained.
Caution against interchanging EQ-5D and 15D for CABG HRQoL or QALY estimates; leaves open optimal instrument choice in cardiac surgery cohorts.
AIMS: Patient-centred outcomes can be measured with different instruments. We compared the performance of two health-related quality-of-life (HRQoL) measures, EQ-5D and 15D, in patients undergoing elective coronary artery bypass grafting (CABG). METHODS AND RESULTS: Patients who were admitted for elective CABG in Kuopio University Hospital Finland in 2012-14 and had completed both instruments concurrently as part of the admission process (n = 182). Follow-up was conducted by postal survey 12 months after the CABG operation. The validity, agreement, and responsiveness to change of both instruments were examined. The mean baseline HRQoL index scores obtained by the EQ-5D and the 15D were 0.795 and 0.859, respectively (P < 0.001 for difference). The agreement between instruments was poor (Spearman's rho = 0.449; P < 0.001). Observed ceiling effects at baseline for the EQ-5D and 15D were 31.9 and 4.4%, respectively. EQ-5D was able to discriminate distinct Canadian Cardiovascular Society groups. During the 1-year follow-up, clinically important improvement was observed in 39.6 and 53.3% of patients with the EQ-5D and the 15D, respectively. However, with the 15D, the number of operated patients required to produce one additional quality-adjusted life year (QALY) was more than twice as high compared with the EQ-5D. CONCLUSION: EQ-5D and 15D do not appear to be interchangeable when patient-centred outcomes in CABG patients are assessed. The EQ-5D seems to have better discriminative power and known-group validity, whereas the 15D is more sensitive to change over time. These instruments lead to significantly different estimates concerning the number of QALYs gained.
No takes yet. Share an insight, caveat, or question.
Heiskanen et al. (2016) conducted a cohort in Elective coronary artery bypass grafting (CABG) (n=182). EQ-5D instrument vs. 15D instrument was evaluated on Mean baseline HRQoL index scores (p=<0.001). The EQ-5D and 15D instruments yielded significantly different baseline HRQoL scores (0.795 vs 0.859; P<0.001) and showed poor agreement in patients undergoing elective CABG.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: