A portable, point-of-care device accurately identifying AF could reduce workload and diagnostic delay by minimizing the need for follow-up 12-lead ECGs.
Does the Plessey imPulse lead I ECG device accurately detect atrial fibrillation compared to a 12-lead ECG in hospital patients?
Does the Plessey imPulse lead I ECG device accurately detect atrial fibrillation compared to a 12-lead ECG in hospital patients?
The imPulse lead I ECG device demonstrates moderate sensitivity and good specificity for detecting atrial fibrillation in a hospital setting, suggesting utility as a point-of-care screening tool.
Answers are grounded in this paper and cite their sources.
Should not yet change AF screening practice; leaves open imPulse accuracy in broader settings pending prospective validation.
BackgroundAtrial fibrillation (AF) increases thromboembolism and stroke risk; this can be reduced by oral anticoagulation, but only if AF is detected. A portable, point-of-care device, capable of accurately detecting and identifying AF, could reduce workload and diagnostic delay by minimizing need for follow-up 12-lead electrocardiogram (ECGs).ObjectiveTo assess the diagnostic performance of the Plessey imPulse lead I ECG device compared with a 12-lead ECG in detecting AF.MethodsCross-sectional diagnostic accuracy study. Participants underwent simultaneous 12-lead ECG and imPulse device recordings. The imPulse device reports AF to be “probable,” “possible,” “unlikely,” or “uncontrolled AF unlikely.” imPulse and ECG reference results were cross-tabulated; sensitivity, specificity, positive/negative predictive values, and positive/negative likelihood ratios with 95% confidence interval (CI) were estimated based on different imPulse device report categorizations and heart rate subgroups.ResultsA total of 217 participants were recruited (mean age 70.2 [standard deviation 12.7]), 56% male, 57% outpatients, 43% inpatients) and 199 were included in analyses. AF was diagnosed on ECG for 41 of 199 (20.6%) participants and reported by imPulse as possible, probable, or uncontrolled AF unlikely present for 49 of 199 (24.6%). Sensitivity and specificity for imPulse detection of possible, probable, or uncontrolled AF unlikely vs unlikely, compared with ECG, were 80.5% (95% CI, 65.1%–91.2%) and 89.9% (84.1%–94.1%), respectively. When probable or uncontrolled AF unlikely were compared vs possible or unlikely AF, sensitivity and specificity were 63.4% (46.9%–77.9%) and 98.1% (94.6%–99.6%), respectively.ConclusionThe imPulse device has moderate sensitivity and good specificity compared with ECG AF detection in a hospital setting. Atrial fibrillation (AF) increases thromboembolism and stroke risk; this can be reduced by oral anticoagulation, but only if AF is detected. A portable, point-of-care device, capable of accurately detecting and identifying AF, could reduce workload and diagnostic delay by minimizing need for follow-up 12-lead electrocardiogram (ECGs). To assess the diagnostic performance of the Plessey imPulse lead I ECG device compared with a 12-lead ECG in detecting AF. Cross-sectional diagnostic accuracy study. Participants underwent simultaneous 12-lead ECG and imPulse device recordings. The imPulse device reports AF to be “probable,” “possible,” “unlikely,” or “uncontrolled AF unlikely.” imPulse and ECG reference results were cross-tabulated; sensitivity, specificity, positive/negative predictive values, and positive/negative likelihood ratios with 95% confidence interval (CI) were estimated based on different imPulse device report categorizations and heart rate subgroups. A total of 217 participants were recruited (mean age 70.2 [standard deviation 12.7]), 56% male, 57% outpatients, 43% inpatients) and 199 were included in analyses. AF was diagnosed on ECG for 41 of 199 (20.6%) participants and reported by imPulse as possible, probable, or uncontrolled AF unlikely present for 49 of 199 (24.6%). Sensitivity and specificity for imPulse detection of possible, probable, or uncontrolled AF unlikely vs unlikely, compared with ECG, were 80.5% (95% CI, 65.1%–91.2%) and 89.9% (84.1%–94.1%), respectively. When probable or uncontrolled AF unlikely were compared vs possible or unlikely AF, sensitivity and specificity were 63.4% (46.9%–77.9%) and 98.1% (94.6%–99.6%), respectively. The imPulse device has moderate sensitivity and good specificity compared with ECG AF detection in a hospital setting.
No takes yet. Share an insight, caveat, or question.
McDonagh et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: