Answers are grounded in this paper and cite their sources.
Objective: The aim of this work was to develop and validate a rapid and simple high-performance liquid chromatography method with a diode- array detector (HPLC-DAD) for determination of favipiravir in bulk and tablet formulations. Methods: The chromatographic analysis was performed at 30 °C with a Poroshell 120EC-C18 column (4.6 x 50 mm, 2.7 µm). The mobile phase was a mixture of 0.1% formic acid in water and 0.1% formic acid in acetonitrile (90:10, v/v). The run time was 5 min at a flow rate of 0.5 mL/min. Results: The proposed method was successfully validated in terms of precision, accuracy, linearity, robustness, limits of detection (LOD) and quantification (LOQ) parameters. The calibration plot was linear over a concentration range of 10-100 µg/mL. The LOD and LOQ values were found to be 0.58 µg/mL and 2.03 µg/mL, respectively. The average recovery values were found to vary from 99.45 percent to 104.29 percent. Conclusion: As a result, it was concluded that the developed method can be used successfully in the determination of favipiravir in pharmaceutical preparations.
No takes yet. Share an insight, caveat, or question.
Duygu Taşkın (2022) studied this question.