Why the study?
Continuous wireless monitoring outside post-anesthesia or intensive care units may enable early detection of deterioration, but requires good accuracy.
Does continuous wireless monitoring provide acceptable agreement with standard wired monitoring for vital signs in postoperative patients?
Does continuous wireless monitoring provide acceptable agreement with standard wired monitoring for vital signs in postoperative patients?
Wireless vital sign monitoring shows acceptable agreement with standard wired monitoring for heart rate, respiratory rate, and blood pressure in postoperative patients, supporting its potential clinical use.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for wireless monitoring in postoperative care; larger prospective studies needed before adoption.
Objective . Continuous wireless monitoring outside the post-anesthesia or intensive care units may enable early detection of patient deterioration, but good accuracy of measurements is required. We aimed to assess the agreement between vital signs recorded by standard and novel wireless devices in postoperative patients. Approach . In 20 patients admitted to the post-anesthesia care unit, we compared heart rate (HR), respiratory rate (RR), peripheral oxygen saturation (SpO 2 ), and systolic and diastolic blood pressure (SBP and DBP) as paired data. The primary outcome measure was the agreement between standard wired and wireless monitoring, assessed by mean bias and 95% limits of agreement (LoA). LoA was considered acceptable for HR and PR, if within ±5 beats min −1 (bpm), while RR, SpO2, and BP were deemed acceptable if within ±3 breaths min −1 (brpm), ±3%-points, and ±10 mmHg, respectively. Main results. The mean bias between standard versus wireless monitoring was −0.85 bpm (LoA −6.2 to 4.5 bpm) for HR, −1.3 mmHg (LoA −19 to 17 mmHg) for standard versus wireless SBP, 2.9 mmHg (LoA −17 to 22) for standard versus wireless DBP, and 1.7% (LoA −1.4 mmHg to 4.8 mmHg) for SpO 2 , comparing standard versus wireless monitoring. The mean bias of arterial blood gas analysis versus wireless SpO 2 measurements was 0.02% (LoA −0.02% to 0.06%), while the mean bias of direct observation of RR compared to wireless measurements was 0.0 brpm (LoA −2.6 brpm to 2.6 brpm). 80% of all values compared were within predefined clinical limits. Significance. The agreement between wired and wireless HR, RR, and PR recordings in postoperative patients was acceptable, whereas the agreement for SpO 2 recordings (standard versus wireless) was borderline. Standard wired and wireless BP measurements may be used interchangeably in the clinical setting.
No takes yet. Share an insight, caveat, or question.
Haahr-Raunkjær et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: