Answers are grounded in this paper and cite their sources.
A solid phase double antibody radioimmunoassay for measuring tissue plasminogen activator (t-PA) in human plasma is described using purified human melanoma cell t-PA and specific goat anti-t-PA IgG. The concentration of t-PA antigen in citrated human plasma sampled at rest was 4.4 +/- 1.3 micrograms/l (mean +/- SD) for healthy individuals (n = 20). After 10 min of venous occlusion the level of t-PA antigen was increased to 13.9 +/- 6.2 micrograms/l. The accuracy was monitored by recovery experiments using plasma from nine healthy individuals and nine patients to which was added low (5 micrograms/l) and high (25 micrograms/l) levels of purified t-PA. The detection limit of the method was estimated as 0.08 micrograms/l. An excellent correlation was found on comparing the t-PA antigen increase with the t-PA activity increase obtained during venous occlusion. In plasma collected prior to venous stasis, the total concentration of detectable t-PA antigen is found mainly in an inactive form. In contrast the t-PA antigen released upon venous occlusion seems to be largely in an active form.
No takes yet. Share an insight, caveat, or question.
Urdén et al. (1984) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: