A proposed pseudostrain-energy function demonstrates that multiaxially-loaded cardiac tissue behaves as nearly transversely-isotropic, highlighting the inadequacy of uniaxial data for predicting multiaxial stresses.
Answers are grounded in this paper and cite their sources.
Models using uniaxial parameters may underestimate multiaxial myocardial stresses; leaves open validated transversely-isotropic constitutive laws for cardiac biomechanics.
A three-dimensional constitutive relation for passive cardiac tissue is formulated in terms of a structurally motivated pseudostrain-energy function, W, while the mathematical simplicity of phenomenological approaches is preserved. A specific functional form of W is proposed on the basis of limited structural information and multiaxial experimental data. The material parameters are determined in a least-squared sense from both uniaxial and biaxial data. Our results suggest that (1) multiaxially-loaded cardiac tissue is nearly transversely-isotropic with respect to local muscle fiber directions, at least for a limited range of strain histories, (2) material parameters determined from uniaxial papillary muscle data result in gross underestimates of the stresses in multiaxially-loaded specimens, and (3) material parameters determined from equibiaxial tests predict the behavior of the tissue under various nonequibiaxial stretching protocols reasonably well.
No takes yet. Share an insight, caveat, or question.
Humphrey et al. (1987) studied this question.