Key result
Peak systolic velocity in the internal carotid artery was the most accurate single Doppler parameter for detecting 70% or greater stenosis (ROC area = 0.94; 0.78 after verification bias correction).
Why the study?
Which Doppler velocity parameter is most accurate for detecting and quantifying carotid artery stenosis compared to angiography?
Observational (n=138)
Which Doppler velocity parameter is most accurate for detecting and quantifying carotid artery stenosis compared to angiography?
Effect estimate: ROC area 0.94
Peak systolic velocity in the internal carotid artery is the best single Doppler parameter for quantifying carotid stenosis and detecting lesions ≥70%.
Supports prioritizing internal carotid peak systolic velocity for stenosis detection; leaves open prospective validation without verification bias.
OBJECTIVE: The purpose of this study was to evaluate and compare the accuracies of the different Doppler velocity parameters used to grade stenoses of the carotid artery. MATERIALS AND METHODS: Seven velocity parameters determined with Doppler spectra were compared with angiographic findings in 138 carotid bifurcations: the peak systolic and peak end-diastolic velocities in the internal and common carotid arteries, the ratios of peak systolic and peak end-diastolic velocities between the internal and common carotid arteries, and the ratio of peak systolic velocity in the internal carotid artery to peak end-diastolic velocity in the common carotid artery. A receiver-operating-characteristic (ROC) analysis was performed, with and without correction for the bias introduced by preferentially selecting patients for angiography, if the Doppler results indicated a lesion. Multiple regression analysis was performed to predict the percent stenosis and to predict the probability of a 70% or greater stenosis. RESULTS: Of the Doppler parameters, the peak systolic velocity in the internal carotid artery and its ratio to the peak end-diastolic velocity in the common carotid artery were the most accurate and had equivalent test performance (ROC area = 0.94; after correction for verification bias, ROC area = 0.78). In multiple regression analysis, the peak systolic velocity in the internal carotid artery was the most significant parameter, although its ratio to the peak end-diastolic velocity in the common carotid artery had incremental value in detecting a 70% or greater stenosis, and the peak systolic velocity in the common carotid artery provided additional information for quantifying the stenosis. CONCLUSION: The peak systolic velocity in the internal carotid artery is the best single velocity parameter for quantifying a stenosis and for detecting a 70% or greater stenosis.
No takes yet. Share an insight, caveat, or question.
Hunink et al. (1993) conducted an observational in Carotid artery stenosis (n=138). Doppler velocity parameters vs. Angiography was evaluated on Accuracy in detecting 70% or greater stenosis (ROC area 0.94). Peak systolic velocity in the internal carotid artery was the most accurate single Doppler parameter for detecting 70% or greater stenosis (ROC area = 0.94; 0.78 after verification bias correction).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: