The pulsewidth-modulated (PWM) current-source inverter (CSI) used in AC motor drive applications can be implemented with symmetric gate turn-off thyristors (GTOs). One of the major difficulties in the optimization of the GTO switch and the snubber components of the inverter is the variation in different switching conditions encountered during normal operation. Past work has concentrated on the GTO and snubber components in voltage-source applications, where commutation of the GTO device is an independent process and does not affect the operation of the other inverter devices. This paper proposes the characterization of the GTO and the snubber components by formulation of the CSI equivalent circuit during the device commutation period. From the equivalent circuit, the state equations are derived, thereby obtaining accurate voltage and current waveforms of the GTO and associated snubbers. From the analysis, the component power loss can be calculated and optimization performed. Simulation results are verified by using both a laboratory prototype and medium-voltage drive system.