PURPOSE: To determine the value of gray-scale ultrasonography (US) and Doppler US in the prediction, diagnosis, and prognostic assessment of hepatic veno-occlusive disease (HVOD). MATERIALS AND METHODS: One hundred patients (median age, 22 years; range, 18 months to 59 years) receiving total body irradiation or busulfan therapy as intensive treatment before hematopoietic stem cell transplantation were studied prospectively. Each patient underwent gray-scale and Doppler US examination before transplantation and weekly thereafter while hospitalized (about four examinations per patient). Seven gray-scale morphologic criteria and seven Doppler criteria were studied, yielding three individual scores: gray-scale score, Doppler score, and total score. RESULTS: Twenty-five patients developed HVOD; nine of these patients died. Positive predictive values of the 14 criteria were 31%-95%, and negative predictive values were 85%-96%. The three scores correlated with the clinical diagnosis of HVOD. Depending on the cutoff value, the positive predictive value of the total score was 44%-89% and the negative predictive value was 91%-98%. The gray-scale and Doppler criteria differed significantly between patients with HVOD and those with graft-versus-host disease of the liver (P = 10(-4)). CONCLUSION: Even if there is overlap in findings between patients with and those without HVOD, gray-scale and Doppler US are valid for positive and differential diagnosis and have predictive and prognostic relevance.
No takes yet. Share an insight, caveat, or question.
Lassau et al. (1997) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: