Key result
Electrocardiographic ST-segment elevation measurement among physicians showed very low inter-rater reliability, with a global kappa coefficient of 0.06 (p < 0.001).
Why the study?
Accurate determination of ST-segment elevation in suspected acute coronary syndrome is essential for urgent reperfusion, but inter-rater reliability among physicians of varying specialties and experience needed assessment.
What is the inter-rater reliability of ST-segment elevation measurement among physicians of different specialties?
Cross-Sectional (n=56)
No
What is the inter-rater reliability of ST-segment elevation measurement among physicians of different specialties?
Effect estimate: global kappa coefficient 0.06
p-value: p=< 0.001
There is very low inter-rater reliability in measuring ST-segment elevation among physicians, highlighting the need for improved training in ECG interpretation for acute coronary syndromes.
Low inter-rater reliability cautions against over-reliance on manual ST elevation for acute MI decisions; leaves open need for standardized training or automated tools.
The accurate determination of the electrocardiographic ST-segment elevation in a patient with clinical suspicion of acute coronary syndrome is essential for treatment with urgent myocardial reperfusion. The aim of this study was to determine the inter-rater reliability of ischemic and non-ischemic ST-segment elevation measurement among physicians with different specialties and experience. We performed an observational, cross-sectional study, with a comparative correlation and paired sampling. 56 physicians from a university hospital in Buenos Aires city were included: Cardiologists from the Coronary Care Unit (CCU) and Cardiology Division, Internal Medicine physicians from the hospitalization, ambulatory care and Emergency divisions, and third- and fourth-year Internal Medicine residents. Each participant analyzed 6 electrocardiograms and was asked to determine the magnitude of the ST-segment elevation at the J-point, and the corresponding diagnosis. The inter-rater coefficient was lower than 0.2, and the global kappa coefficient was 0.06 (p < 0.001). The global correct interpretations were: inferior wall myocardial infarction (MI): 89.3%; anterior wall MI: 51.8%; lateral wall MI: 75%; left bundle branch block: 91.1%; left ventricle hypertrophy: 44.6%; acute pericarditis: 25%. We believe that the low correlation was probably due to the difficulty in determining the J-point. These findings could suggest the need to strengthen the electrocardiographic concepts of ischemia, and the differentiation between ischemic and non-ischemic ST-segment elevations.
No takes yet. Share an insight, caveat, or question.
Ignacio Martín Santarelli (2019) conducted a cross-sectional in Acute coronary syndrome suspicion (n=56). Electrocardiographic ST-segment elevation measurement was evaluated on Inter-rater reliability of ischemic and non-ischemic ST-segment elevation measurement (global kappa coefficient 0.06, p=< 0.001). Electrocardiographic ST-segment elevation measurement among physicians showed very low inter-rater reliability, with a global kappa coefficient of 0.06 (p < 0.001).