The detection of furfural in transformer insulating oil is a core method for assessing the aging state of oil-paper insulation. Furfural, as a key marker of cellulose insulation degradation, can indirectly reflect the remaining life of the transformer. To achieve fast and non-destructive detection, this study employs Terahertz Time-Domain Spectroscopy (THz-TDS) combined with a customized sealed sample cell to conduct transmission spectral tests on mineral insulating oil samples with varying degrees of aging, obtaining refractive index, absorption coefficient, and frequency domain characteristic parameters. Experimental results show that furfural molecules exhibit significant characteristic absorption peaks in the terahertz frequency range (such as 1.4 THz), and the absorption intensity has a good linear relationship with the concentration of furfural in the oil, confirming the high sensitivity of terahertz technology for detecting trace amounts of furfural (as low as mg/L level). Although the feasibility of terahertz spectroscopy has been demonstrated in current research, future studies will require the integration of Density Functional Theory (DFT) simulations and machine learning algorithms to further analyze the furfural-oil molecule interaction mechanism and establish high-precision quantitative inversion models, improving the detection efficiency and reliability of trace aging products in complex oil-based systems.
No takes yet. Share an insight, caveat, or question.
Cheng et al. (2025) studied this question.