Key result
Electrophysiologic study using His bundle electrograms in 21 patients with AV conduction defects identified delayed intra-atrial conduction in 2 patients during sinus rhythm.
Observational (n=21)
His bundle electrograms can identify intra-atrial conduction delay as a mechanism for first-degree heart block in a subset of patients with AV conduction defects.
With the use of His bundle electrograms, intra-atrial conduction delay has been found to be a cause offirstdegree heart block. Twenty-one patients with evidence of atrioventricular conduction defects or dysrhythmias were studied with His bundle electrograms and 2 were found to have delayed intra-atrial conduction while in sinus rhythm. A further 3 patients had normal PA intervals during sinus rhythm but prolonged StA intervals during atrial pacing. The significance of this is discussed.
No takes yet. Share an insight, caveat, or question.
Millar et al. (1973) conducted an observational in Atrioventricular conduction defects or dysrhythmias (n=21). His bundle electrograms was evaluated on Delayed intra-atrial conduction. Electrophysiologic study using His bundle electrograms in 21 patients with AV conduction defects identified delayed intra-atrial conduction in 2 patients during sinus rhythm.